نتایج جستجو برای: gels radiometry dose

تعداد نتایج: 334116  

2012
Ibrahim M. El-Bagory Mohsen A. Bayomi Gamal M. Mahrous Fars K. Alanazi Ibrahim A. Alsarra

Gamma irradiation was tested as a method for sterilization of pluronic F-127 gel to be used for ocular delivery of ciprofloxacin (CFX). The effect of gamma irradiation on the properties of pluronic gels was studied at different irradiation doses and pluronic copolymer concentrations. The flow of pluronic gels of different concentrations was non-Newtonian with thixotropic pseudoplastic propertie...

2000
A. Irwin J. Oleson Richard Robinson

The advent of high resolution infrared resistor arrays, has greatly increased the level of fidelity of infrared sensor testing that can be accomplished in the cost effective laboratory environment. However, the sensor output image quality depends on the uniformity of the projector array. In addition to the advanced proprietary design and fabrication process used to create a highly uniform emitt...

2015
Ian Mcgowan Ross D. Cranston Kathryn Duffill Aaron Siegel Jarret C. Engstrom Alexyi Nikiforov Cindy Jacobson Khaja K. Rehman Julie Elliott Elena Khanukhova Kaleab Abebe Christine Mauck Hans M. L. Spiegel Charlene S. Dezzutti Lisa C. Rohan Mark A. Marzinke Hiwot Hiruy Craig W. Hendrix Nicola Richardson-Harman Peter A. Anton

OBJECTIVES The CHARM-01 study characterized the safety, acceptability, pharmacokinetics (PK), and pharmacodynamics (PD) of three tenofovir (TFV) gels for rectal application. The vaginal formulation (VF) gel was previously used in the CAPRISA 004 and VOICE vaginal microbicide Phase 2B trials and the RMP-02/MTN-006 Phase 1 rectal safety study. The reduced glycerin VF (RGVF) gel was used in the MT...

2013
Cheng-Ting Shih Jui-Ting Hsu Rou-Ping Han Bor-Tsung Hsieh Shu-Jun Chang Jay Wu

Polymer gels are regarded as a potential dosimeter for independent validation of absorbed doses in clinical radiotherapy. Several imaging modalities have been used to convert radiation-induced polymerization to absorbed doses from a macro-scale viewpoint. This study developed a novel dose conversion mechanism by texture analysis of scanning electron microscopy (SEM) images. The modified N-isopr...

2016
Kai-Yuan Cheng Ling-Ling Hsieh Cheng-Ting Shih

Polymer gel dosimeters have been proven useful for dose evaluation in radiotherapy treatments. Previous studies have demonstrated that using a polymer gel dosimeter requires a 24 h reaction time to stabilize and further evaluate the measured dose distribution in two-dimensional dosimetry. In this study, the short-term stability within 24 h and feasibility of N-isopropylacrylamide (NIPAM) polyme...

Journal: :The Journal of infectious diseases 2003
Begoña Ruiz-Perez Ronald L Cisneros Tetsuya Matsumoto Robert J Miller George Vasios Pericles Calias Andrew B Onderdonk

Sodium hyaluronate-carboxymethylcellulose (HA/CMC) formulations are gels that effectively reduce postoperative adhesions in both animals and humans, when placed in the peritoneal or pelvic cavities concomitant with surgical manipulation. However, it has been suggested that the use of these products may increase the risk of peritoneal infection after contamination with intestinal contents during...

Journal: :Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 2004
Ulla Ramm Jussi Moog Belinda Spielberger Achim Bankamp Heinz-Dietrich Bottcher Gerhard Kraft

In this presentation BANG polymer-gel dosimetry using magnetic resonance imaging (MRI) is applied to densely ionizing radiation such as carbon ion beams. BANG polymer-gels were irradiated with monoenergetic 12C ions at an energy of 205 MeVu(-1). The irradiation of the gels with doses up to 100 Gy were performed at the radiotherapy facility of the GSI, Darmstadt, Germany. For comparison with spa...

Journal: :IEEE Transactions on Pattern Analysis and Machine Intelligence 2002

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید