نتایج جستجو برای: glucose oxidase gox

تعداد نتایج: 231232  

Journal: :Analytical biochemistry 2006
Hongtao Zhao Huangxian Ju

A bilayer of the polyelectrolytes poly(dimethyldiallylammonium chloride) (PDDA) and poly(sodium 4-styrenesulfonate) (PSS) was formed on a 3-mercapto-1-propanesulfonic-acid-modified Au electrode. Subsequently, multiwall carbon nanotubes (MWCNTs) wrapped by positively charged PDDA were assembled layer-by-layer with negatively charged glucose oxidase (GOx) onto the PSS-terminated bilayer. Electroc...

Journal: :international journal of nano dimension 0
o. ramezani azghandi young researchers club, quchan branch, islamic azad university, quchan, iran. a. farahbakhsh department of chemical engineering, quchan branch, islamic azad university, quchan, islamic republic of iran.

the glucose oxidase (gox) electrochemical sensors were used to detect a little amount of glucose. in this paper, the pure platinum plate (length of 5 cm and a width of 3 mm), the ag/agcl electrode and platinum electrode (diameter of 1 mm) were applied as a working electrode (w.e), reference electrode and auxiliary electrode sequential. factors measured, glucose concentration and ph is phosphate...

Journal: :The Plant cell 2012
Clemencia M Rojas Muthappa Senthil-Kumar Keri Wang Choong-Min Ryu Amita Kaundal Kirankumar S Mysore

In contrast to gene-for-gene disease resistance, nonhost resistance governs defense responses to a broad range of potential pathogen species. To identify specific genes involved in the signal transduction cascade associated with nonhost disease resistance, we used a virus-induced gene-silencing screen in Nicotiana benthamiana, and identified the peroxisomal enzyme glycolate oxidase (GOX) as an ...

Journal: :Proceedings of the National Academy of Sciences of the United States of America 2016
Jeffrey E Dick Adam T Hilterbrand Lauren M Strawsine Jason W Upton Allen J Bard

We report the specific collision of a single murine cytomegalovirus (MCMV) on a platinum ultramicroelectrode (UME, radius of 1 μm). Antibody directed against the viral surface protein glycoprotein B functionalized with glucose oxidase (GOx) allowed for specific detection of the virus in solution and a biological sample (urine). The oxidation of ferrocene methanol to ferrocenium methanol was car...

2017
YUANMO WANG

During neuronal communication neurotransmitters are released through the process exocytosis that occurs on the time scale of sub-milliseconds to milliseconds. Neuronal activity by neurotransmitters that are non-electroactive cannot easily be monitored due to limitations in the temporal resolutions of the sensor probes for these analytes. In order to achieve a fast detection of the rapid transie...

Journal: :Applied and environmental microbiology 1998
S Witt M Singh H M Kalisz

The gene coding for Penicillium amagasakiense glucose oxidase (GOX; beta-D-glucose; oxygen 1-oxidoreductase [EC 1.1.3.4]) has been cloned by PCR amplification with genomic DNA as template with oligonucleotide probes derived from amino acid sequences of N- and C-terminal peptide fragments of the enzyme. Recombinant Escherichia coli expression plasmids have been constructed from the heat-induced ...

Journal: :Yakugaku zasshi : Journal of the Pharmaceutical Society of Japan 2015
Katsuhiko Sato

Functional multilayer thin films have been prepared by layer-by-layer (LbL) deposition for the development of sensors, separators, and drug delivery systems. In particular, glucose-sensitive LbL films have been widely studied for use as glucose sensors and in glucose-triggered drug delivery systems. In this work, I report on glucose-sensitive LbL films that consist of concanavalin A (ConA), phe...

2018
Ambran Hartono Edi Sanjaya Ramli Ramli

A polyvinylidene fluoride (PVDF) film-based capacitive biosensor was developed for glucose sensing. This device consists of a PVDF film sandwiched between two electrodes. A capacitive biosensor measures the dielectric properties of the dielectric layers at the interface between the electrolyte and the electrode. A glucose oxidase (GOx) enzyme was immobilized onto the electrode to oxidize glucos...

Journal: Journal of Nanoanalysis 2017

Enzymes Immobilization onto different types of the substrate could be helpful in various applicationsof biomedical devices and biosensors. Enzyme activity and stability could be affected by support andmethod of immobilization. In this study, the silver metal foam was successfully synthesized by thesoft-shell method and then was coated with silica. Then, glucose oxidase (GOx) immobilized on nonc...

Journal: :Dalton transactions 2010
Lai Truong Phuoc Paco Laveille Françoise Chamouleau Gilbert Renard Jullien Drone Bernard Coq François Fajula Anne Galarneau

Solid polyenzymatic biocatalysts have been designed by combining two immobilized enzymes, the first one allowing the in situ generation of H(2)O(2) from air and the second one performing an oxidation reaction. The in situ H(2)O(2) generation system is based on the reaction of glucose with air using a glucose oxidase (GOx). The optimization of the encapsulation of GOx into phospholipids-template...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید