نتایج جستجو برای: implantable cardioverter defibrillator

تعداد نتایج: 19988  

Journal: :Journal of the American College of Cardiology 2011

2016
Tantchou Tchoumi Jacques Cabral Appolonia Budzee Gianfranco Butera

Sudden cardiac deaths, which account for approximately 350 000 deaths each year, is a major health care problem. Antiarrhythmic drugs have not been reliable in preventing sudden cardiac death. Although β-blockers, angiotensin-converting enzyme inhibitors, and revascularization play a role in prevention of sudden cardiac death, the development and subsequent refinement of the implantable cardiov...

2013
Ilknur Can Venkatakrishna Tholakanahalli

A 58 year-old-patient developed an episode of polymorphic atrial tachycardia which looked like "atrial torsades de pointes" after a 5J shock from implantable cardioverter defibrillator.

Journal: :Circulation. Arrhythmia and electrophysiology 2013
Carmine Muto Francesco Solimene Paolo Gallo Maurizio Nastasi Concetto La Rosa Raimondo Calvanese Raffaele Iengo Michelangelo Canciello Raffaele Sangiuolo Igor Diemberger Carmine Ciardiello Bernardino Tuccillo

BACKGROUND Current recommendations require a QRS duration of ≥120 ms as a condition for prescribing cardiac resynchronization therapy (CRT). This study was designed to test the hypothesis that patients with heart failure (HF) of ischemic origin, current indications for defibrillator implantation, and QRS <120 ms may benefit from CRT in the presence of marked mechanical dyssynchrony. METHODS A...

Journal: :Circulation 2011
Siqin Ye Matthew Grunnert Jens Jakob Thune Kent M Stephenson Hajime Uno Peter V Finn John J V McMurray Eric J Velazquez Robert Califf Marc A Pfeffer Scott D Solomon

BACKGROUND Sudden death (SD) is a frequent catastrophic complication in patients after myocardial infarction. Circumstances of SD may affect strategies for prevention. METHODS AND RESULTS We reviewed source documentation for 1067 patients who had SD in the Valsartan in Acute Myocardial Infarction Trial (VALIANT) trial. We determined the circumstances of these events and assessed long-term mor...

Journal: :Circulation. Heart failure 2013
David H Birnie Andrew Ha Lyall Higginson Kiran Sidhu Martin Green François Philippon Bernard Thibault George Wells Anthony Tang

BACKGROUND The impact of QRS morphology and duration on the effectiveness of cardiac resynchronization therapy (CRT) has been usually assessed separately. The interaction between these 2 simple ECG parameters and their effect on CRT has not been systematically assessed in a large-scale clinical trial. METHODS AND RESULTS The Resynchronization-Defibrillation for Ambulatory Heart Failure Trial ...

2010
Jeanne E. Poole Mina K. Chung Daniel Z. Uslan Venkateshwar Gottipaty

Background—Prospective studies defining the risk associated with pacemaker or implantable cardioverter-defibrillator replacement surgeries do not exist. These procedures are generally considered low risk despite results from recent retrospective series reporting higher rates. Methods and Results—We prospectively assessed predefined procedure-related complication rates associated with elective p...

Journal: :Circulation 2010
Jeanne E Poole Marye J Gleva Theofanie Mela Mina K Chung Daniel Z Uslan Richard Borge Venkateshwar Gottipaty Timothy Shinn Dan Dan Leon A Feldman Hanscy Seide Stuart A Winston John J Gallagher Jonathan J Langberg Kevin Mitchell Richard Holcomb

BACKGROUND Prospective studies defining the risk associated with pacemaker or implantable cardioverter-defibrillator replacement surgeries do not exist. These procedures are generally considered low risk despite results from recent retrospective series reporting higher rates. METHODS AND RESULTS We prospectively assessed predefined procedure-related complication rates associated with elective...

Journal: :Journal of cardiovascular electrophysiology 2007
Jennifer Cowger Matthews Daphne Betley Fred Morady Frank Pelosi

An increasing number of patients have a coexisting implantable cardioverter defibrillator (ICD) and left ventricular assist device (LVAD) to treat ventricular arrhythmias and refractory heart failure, respectively. To date, there have been no published reports of negative interactions between these devices that have impacted appropriate ICD or LVAD function. In this case report, we describe a p...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید