نتایج جستجو برای: liquid membrane electrode

تعداد نتایج: 654404  

Journal: :Clinical chemistry 1991
M Fujiwara

Ion-selective electrodes (ISEs) are widely used in clinical examinations. The mechanisms of ISEs have been studied to develop a disposable ISE for "dry chemistry" analyses. The behavior of Na+ and Ag+ in an ion-selective polymer liquid membrane (ISM) containing methyl monensin (MMO), which is selective for Na+, has been clarified by x-ray microanalysis and measurement of electrical potential. T...

Journal: :علوم و تکنولوژی پلیمر 0
معصومه باقری دانشگاه شهید مدنی آذربایجان محمد هاشم پور دانشگاه شهید مدنی آذربایجان

the rapidly increasing interest in functional materials with reversibly switchable physico- chemical properties has led to significant work on the development of stimuli responsive membranes. thermotropic liquid crystals with their exceptional properties have potentials for drug-delivery applications. thermoresponsive liquid-crystal-embedded membranes were investigated for the purpose of develo...

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2010
mohammad mazloum-ardakani roya mazidi mohammad hossein mashhadizadeh hossein naeimi kobra rabiei

in this work we introduce a practical use of synthesized schiff base metal complex in sensing application. a new perchlorate-selective electrode based on the complex n, n'-4-nitro-phenylmethanebis-(salicylaldiminato) copper (ii) [cul] as the membrane carrier was developed. the electrode exhibits a good  nernstian slope of -55.0 ± 1.0 mv/decade and a linear range of  for perchlorate. the limit o...

Journal: :journal of chemical and petroleum engineering 2015
babak mokhtarani hossein khormaei mohammad hasan amini hamid reza mortaheb

liquid membrane processes have attracted many interests in recent years for removal of heavy metals such as cadmium from industrial wastewaters. in this study, a modified hybrid liquid membrane system is introduced. the setup is worked by applying the water-insoluble dioctyl phthalate as the organic solvent. n-octanol and tetra butyl ammonium bromide are added to the organic phase to increase t...

Journal: :journal of physical & theoretical chemistry 2009
m. zawari m. giahi h. aghaie

in this research, a pvc membrane electrode for manganese (ii) ions based on n-(2-picolinamidoethyl)picolinamide as neutral carrier was prepared. the electrode exhibits a nemstian responseover mn(ii) concentration range of (1.0 x10-5 t01.0 x 10-1m) with a slope of 29.3±0.5 mv perdecade of concentration with a working ph range of 4.0-9.0. it has a fast response time (

Babak Mokhtarani Hamid Reza Mortaheb Hossein Khormaei Mohammad Hasan Amini

Liquid membrane processes have attracted many interests in recent years for removal of heavy metals such as cadmium from industrial wastewaters. In this study, a modified hybrid liquid membrane system is introduced. The setup is worked by applying the water-insoluble dioctyl phthalate as the organic solvent. N-octanol and tetra butyl ammonium bromide are added to the organic phase to increase t...

2000
I. Poels A. van den Berg

Ž . Ž . An ion-selective field effect transistor ISFET was applied as a potentiometric detector in liquid chromatography LC for the Ž determination of organic acids. The ISFET was prepared by coating the gate insulator of the encapsulated transistor with a poly vinyl . Ž . chloride PVC matrix membrane containing methyltridodecylammoniumchloride, which enables the detection of organic anions. Th...

Journal: :physical chemistry and electrochemistry 0
elham eslami department of chemistry, kazerun branch, islamic azad university, kazerun, iran fatemeh farjam department of chemistry, marvdasht branch, islamic azad university, marvdasht, iran

we used an effective electrochemical sensor for the determination of imipramine at ph 7.2 using a carbon nanocomposite electrode. the electrode has been designed by incorporation of montmorillonite nanoclay into the carbon ionic liquid electrode. the high sensitivity of 1.714 μa (μm)-1, two linear calibration ranges of 0.1–2 μm and 2-40 μm, and detection limit of 19 nm were achieved. the relati...

Journal: :journal of physical & theoretical chemistry 2004
hossein aghaei masood giahi majjid arvand mehran aghaei

tin(ii)-ion-selective electrode consisting of dibenzo-18-crown-6 (db18c6) as an ionophore inpvc matrix was developed. the influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. the electrodeshowed a near nernstian response for sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27...