Scatter in a detector and its housing can result in image degradation. Typically, such scatter leads to a low-spatial frequency 'glare' superimposed on the primary signal. We infer the glare-spread function (GSF) of an amorphous-silicon flat-panel detector via an edge-spread technique. We demonstrate that this spread (referred to as 'scatter-glare' herein) causes a low-spatial frequency drop in...
computed tomographyrepresents about 10% of all diagnostic radiology procedures, but it isresponsible for almost 50% - 60% of exposure from diagnostic procedures. inhead ct, other critical organs such as eye lenses and thyroids are in theradiation field. therefore, dose assessment in these organs is very important.the aim of this study is to estimate the absorbed dose in critical organs ofpatien...
Image-guided radiation therapy using cone-beam computed tomography (CBCT) is becoming routine practice in modern radiation therapy. The purpose of this work was to develop an imaging QA program for CT and CBCT units in our department, based on the American College of Radiology (ACR) CT accreditation phantom. The phantom has four testing modules, permitting one to test CT number accuracy, slice ...
Drawing regions of interest (ROIs) in positron emission tomography/computed tomography (PET/CT) scans of the National Electrical Manufacturers Association (NEMA) NU-2 Image Quality (IQ) phantom is a time-consuming process that allows for interuser variability in the measurements. In order to reduce operator effort and allow batch processing of IQ phantom images, we propose a fast, robust, autom...
Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...
UNLABELLED In dual-modality PET/CT systems, the CT scan provides the attenuation map for PET attenuation correction. The current clinical practice of obtaining a single helical CT scan provides only a snapshot of the respiratory cycle, whereas PET occurs over multiple respiratory cycles. Misalignment of the attenuation map and emission image because of respiratory motion causes errors in the at...
Introduction: whole body bone scan is one of the most useful procedures of nuclear medicine. Accurate distribution of radiopharmaceutical is yielded by using SPECT-CT. There are concerns about the radiation dose of CT part. The present study aimed to evaluate the patients’ dose in bone nuclear medicine imaging. Methods and Materials: First of all, the dose report of CT console was calibrated u...
Introduction: One of the most important parameters in x-ray CT imaging is the noise induced by detected scattered radiation. The detected scattered radiation is completely dependent on the scanner geometry as well as size, shape and material of the scanned object. The magnitude and spatial distribution of the scattered radiation in x-ray CT should be quantified for development of robust scatter...
Purpose. To evaluate the influence of effective energy on computed tomography (CT) number in monoenergetic images (MEIs). Methods. Three bottle phantoms filled with water, oil, and a contrast agent were scanned at 100 and 140 kVp tube energy with a dual-source CT scanner. Cardiac dual-energy CT data was collected from 17 patients. CT numbers were measured in the 3 phantom materials and in the l...
Background: The artificial neural networks (ANNs) are useful in solving nonlinear processes, without the need for mathematical models of the parameters. Since the relationship between the CT numbers and material compositions is not linear, ANN can be used for obtaining tissue density and composition.Objective: The aim of this study is to utilize ANN for determination of the composition and mass...