نتایج جستجو برای: phantom scatter factor
تعداد نتایج: 870740 فیلتر نتایج به سال:
introduction: scatter radiation is one of the major sources of error in nuclear medicine data processing. different methods of scatter correction have been introduced in order to improve the quality of data. however the best method is to avoid recording of scatter photons in acquisition. the only difference between scattered and non-scattered photons is the energy. pulse height analyzer is the ...
In positron emission tomography (PET), photon scattering inside the body causes significant blurring and quantification error in the reconstructed images. To solve this problem we have developed Monte Carlo (MC) based 3D PET reconstruction algorithms implemented on the Graphics Processing Unit (GPU). Our implementation takes multiple Compton scattering into account without any significant addit...
Monte Carlo simulation is a very powerful tool in understanding performances of positron tomographs as well as in assessing image reconstruction algorithms and their implementations. We present an object-oriented Monte Carlo simulator developed for 3D positron tomography. Results from phantom simulation studies including absorption and scattering of the photons in the field-of-view are presente...
PURPOSE A phantom study was conducted to evaluate the feasibility of body contour definition with Compton scatter photons from external sources of technetium-99m pertechnetate (Tc-99m) to create a fusion image of CT and SPECT images. METHODS External sources of 1 mCi (37 MBq) Tc-99m were placed on each collimator, and body-contour SPECT images were obtained with an energy window of 100 keV +/...
The presence of dental metals creates radiation dose perturbation due to scattered radiation during radiation therapy for the head and neck region. The purpose of our study was to compare the scatter doses resulting from various dental metals in the direction of the buccal mucosa among a single-field technique, three-dimensional conformal radiation therapy (3D CRT), and intensity-modulated radi...
introduction: the key characteristics of positron emission tomography (pet) are its quantitative capability and its sensitivity, which allow the in vivo imaging of biochemical interactions with small amounts of tracer concentrations. therefore, accurate quantification is important. however, it can be sensitive to several physical factors. the aim of this investigation is the assessment of the e...
The purpose of this study is to characterize the x-ray properties of a dual-modality, anthropomorphic breast phantom whose MRI properties have been previously evaluated. The goal of this phantom is to provide a platform for optimization and standardization of two- and three-dimensional x-ray and MRI breast imaging modalities for the purpose of lesion detection and discrimination. The phantom is...
A Dark-field Scanning Spectroscopy Platform for Localized Scatter and Fluorescence Imaging of Tissue
ABSTRACT Tissue ultra-structure and molecular composition provide native contrast mechanisms for discriminating across pathologically distinct tissue-types. Multi-modality optical probe designs combined with spatially confined sampling techniques have been shown to be sensitive to this type of contrast but their extension to imaging has only been realized recently. A modular scanning spectrosco...
Several national and international protocols have been established for the dosimetry of x-ray beams used in radiotherapy. For the very low energy x-rays (0.035 mm1.0 mm Al HVL) only two codes are available: the UK IPEMB Code of Practice and the German standard, DIN 6809 Part 4. The measurement of very low energy x-ray beams is normally performed with parallel plate ionization chambers calibrate...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید