نتایج جستجو برای: polymer gel treatment

تعداد نتایج: 1570732  

Journal: :The Journal of infectious diseases 1999
N Bourne D I Bernstein J Ireland A J Sonderfan A T Profy L R Stanberry

Vaginal gel formulations containing the naphthalene sulfonate polymer PRO 2000 are being developed as topical microbicides to protect against infection with sexually transmitted disease (STD) pathogens. A mouse model was used to determine whether PRO 2000 could protect against genital herpes in vivo. Animals received a single intravaginal application of 15 microL of a 10% PRO 2000 aqueous solut...

Journal: :Chemical communications 2016
Xiao-Guang Sun Youxing Fang Xueguang Jiang Kazuki Yoshii Tetsuya Tsuda Sheng Dai

A polymer gel electrolyte using AlCl3 complexed acrylamide as a functional monomer and acidic ionic liquid based on a mixture of 1-ethyl-3-methylimidazolium chloride (EMImCl) and AlCl3 (EMImCl-AlCl3, 1-1.5, in molar ratio) as a plasticizer has been successfully prepared for the first time via free radical polymerization. Aluminum deposition is successfully achieved using a polymer gel electroly...

M. Allahverdi M. Sedaghat M.H Zahmatkesh R. Jaberi Sh. Akhalghpoor

Introduction: Despite the fact that the clinical implementation of polymer gel dosimetry has been facilitated after the introduction of normoxic gels, there are still complications in its clinical routine use that are under investigation. In the current work, the feasibility of using a normoxic polymer gel dosimeter named MAGICA has been investigated for use in our clinical brachytherapy applic...

Journal: :BioImpacts : BI 2013
Farideh Pak Alireza Farajollahi Ali Movafaghi Alireza Naseri

INTRODUCTION At present, the polymer gel dosimeter is considered to be the best possible dosimeter for measuring 3-dimesional radiation dose distribution in radiotherapy. These gels are normally toxic; therefore, manufacturing, handling and discarding them require special attention. In order to find less toxic recipe, N-isopropyle acrylamide polymer gel (NIPAM) was introduced. In this study, th...

Journal: :Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics 2008
B Hill A J Venning C Baldock

Polymer gel dosimetry undertaken on a multislice CT scanner provides an alternative method to conventional dosimetry measurements. Polymer gel dosimeters were used to measure CT radiation doses and compared to TLD and ionization chamber measurements in different diameter phantoms. CTDI was investigated for each of these phantoms for a range of mAs (100-400 mAs), tube voltage (100-135 kV) and no...

Journal: :journal of biomedical physics and engineering 0
m. mahdavi ph.d, physics depart- ment, mazandaran uni- versity, babolsar, iran m. khadem-abolfazli m.sc, para medical de- partment, babol univer- sity of medical sciences, babol, iran s. r. m. mahdavi ph.d, medical physics department, tehran university of medical sci- ences, tehran, iran gh. ataei m.sc, para medical de- partment, babol univer- sity of medical sciences, babol, iran

background: radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date. objective: the aim of this study is an investigating of percentage depth dose enhancement within the gel medium with used of conformal distribution gold nanoparticle as contrast agents by high atomic number material. methods: in this work...

Journal: :علوم و تکنولوژی پلیمر 0
مجید پاکیزه محمدرضا امیدخواه رامین کریم زاده عبدالصمد زرین قلم

0

Fatemeh Sadat Ghoreshi Issac Shiri Jaber Beik Keikhosro Keshavarzi Seyed Rabee Mahdi Mahdavi

Introduction: Currently, the potential application of gold nanoparticles (AuNPs) to increase the efficiency of radiation therapy have been investigated. However, the loss of an appropriate method to estimate the dose distribution in nanoparticle laden tissue limits the applicability of nanoparticles in radiotherapy clinics. Polymer gel dosimetry provides an accurate and precise...

اربابی, عظیم, بلوری, بهرام, ندایی, حسن, قهرمان اصل, روح اله,

  Background & Aim: Nowadays, radiosensitive polymer gels are used as a reliable dosimetry tool for verification of 3D dose distributions. Polymer gel dosimeters consist of an aqueous mixture of monomers and a gelling agent, which after irradiation, 3D dose distribution is acquired by using imaging techniques. The aim of this study is to evaluate the application and capability of normoxic polym...

2012
N. Gopishankar S. Vivekanandhan S.S. Kale G.K. Rath S. Senthilkumaran S. Thulkar V. Subramani M.A. Laviraj R.K. Bisht A.K. Mahapatra

This work illustrates a procedure to assess the overall accuracy associated with Gamma Knife treatment planning using plugging. The main role of source plugging or blocking is to create dose falloff in the junction between a target and a critical structure. We report the use of MAGAT gel dosimeter for verification of an experimental treatment plan based on plugging. The polymer gel contained in...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید