In this research, a coated graphite electrode was constructed for determination of Mg2+ in pharmaceutical supplements. The designed sensor demonstrates an ideal Nernstian slope (30.1 mV. Decade-1) over a wide concentration range (1×10-6- 1×10-1 Mol L-1). The selectivity of the sensor was evaluated over 16 different cations by matched potential method and no serious interference was observed fro...

2012
M. K. Dwivedi Suresh Jain

A PVC-based membrane of 12-crown-4 exhibits good response for Zn2+ in a wide concentration range (7.08  10-5-1.00  10-1 M) with a non-nernstian slope of 20.5 mv per decade of concentration of Zn2+. The response time of sensor is <10 s and the membrane can be used for more than 3 months without observing any divergence. In addition, the proposed sensor exhibits very good selectivity for Zn2+ o...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2014
Mohamed A F Elmosallamy Alaa S Amin

New, simple and convenient potentiometric and spectrophotometric methods are described for the determination of dextromethorphan hydrobromide (DXM) in pharmaceutical preparations. The potentiometric technique is based on developing a potentiometric sensor incorporating the dextromethorphan tetrakis(p-chlorophenyl)borate ion-pair complex as an electroactive species in a plasticized PVC matrix me...

In the present study, we investigate the potentiometric behavior of Cu2+ carbon paste electrodes based on two mercapto compounds 2-Ethylmino-5-Mercapto-1,3,4-Thiadiazole (EAMT) and 2-Acetylamino-5-mercapto-1,3,4-thiadiazole (AAMT) self-assembled on gold nano-paricle (GNP) as ionophore. Then, the results obtained from the modified electrodes are compared. The self-assembled ionophores exhibit a ...

E. Baghdar M. Aghaie M. Giahi M. H. Fekri S. Farhadi

In order to study the Cu(II) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of PVC powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. The sensor showed a near Nernstian response for Cu(II) ions over a concentration range from 1.0×0-6 –1.0×0-2 M with a slope of 28.90.5 mV per concentration decade with a working pH range of 3.5-6.3. ...

2013
S. Wiegärtner G. Hagen J. Kita J. Spallek C. Schmaus A. Kießig A. Bolz R. Moos

In this work, a planar solid-state potentiometric CO2 sensor for medical applications of the type CO2, O2, Au, Li2CO3-BaCO3 | Nasicon | Na2Ti6O13-TiO2, Au, O2, CO2 was developed in thick-film technology. Due to an integrated screen-printed platinum heater on the rear side, the sensor can be applied without changing its working temperature of 525°C in the main flow of the respiratory air of an i...