Journal: :Physics in medicine and biology 2005
A S Kirov J Z Piao N K Mathur T R Miller S Devic S Trichter M Zaider C G Soares T LoSasso

The need for fast, accurate and high resolution dosimetric quality assurance in radiation therapy has been outpacing the development of new and improved 2D and 3D dosimetry techniques. This paper summarizes the efforts to create a novel and potentially very fast, 3D dosimetry method based on the observation of scintillation light from an irradiated liquid scintillator volume serving simultaneou...

Journal: :iranian journal of medical physics 0
micaeil mollazadeh m.sc. student in medical physics, medical physics and engineering dept., tehran university of medical sciences, tehran, iran. mahmood allahverdi associate professor, medical physics and engineering dept., tehran university of medical sciences, tehran, iran. tayyeb allahverdi pourfallah assistant professor, biochemistry and biophysics dept., mazandaran university of medical sciences, sari, iran. nader riahi alam associate professor, medical physics and engineering dept., tehran university of medical sciences, tehran, iran. mohammadreza ay associate professor, medical physics and engineering dept., tehran university of medical sciences, tehran, iran.

introduction: gafchromic ebt films are one of the self-developing and modern films commercially available for dosimetric verification of treatment planning systems (tpss). their high spatial resolution, low energy dependence and near-tissue equivalence make them suitable for verification of dose distributions in radiation therapy. this study was designed to evaluate the dosimetric parameters of...

Journal: :Physics in Medicine and Biology 2005

2014
Mishra Subhalaxmi T. Palani Selvam

Relative absorbed dose energy response correction, R, for various radiochromic films in water phantom is calculated by the use of the Monte Carlo-based EGSnrc code system for high energy brachytherapy sources 60Co, 137Cs, 192Ir and 169Yb. The corrections are calculated along the transverse axis of the sources (1-15 cm). The radiochromic films investigated are EBT, EBT2 (lot 020609 and lot 03110...

2014
Katherine Mellis Timmy Siauw Atchar Sudhyadhom Rajni Sethi I-Chow Hsu Jean Pouliot Adam Cunha

Purpose: To evaluate the radiation attenuation properties of PC-ISO, a bio-compatible, sterilizable 3D printing material and its suitability for customized gynecologic (GYN) brachytherapy 15 applicators. Method: A custom radiochromic film dosimetry apparatus was 3D-printed in PC-ISO. The apparatus contained a single catheter channel and a slit to hold a radiochromic segment. A brachytherapy dos...

Journal: :Physics in medicine and biology 2004
Martin J Butson Tsang Cheung Peter K N Yu

The visible absorption spectra of Radiachromic FWT-60 radiochromic film have been investigated to analyse the dosimetry characteristics of the film. The film is radiation sensitive to high absorbed doses. The visible absorption spectra of this film when exposed to photon radiation show a peak at 605 nm which is stable over the dose range of 0 Gy to 20 kGy. The radiation sensitive absorption spe...

Journal: :Physics in medicine and biology 1998
M J Butson P K Yu P E Metcalfe

Both read-out light sources and ambient light sources can produce a marked effect on coloration of radiochromic film. Fluorescent, helium neon laser, light emitting diode (LED) and incandescent read-out light sources produce an equivalent dose coloration of 660 cGy h(-1), 4.3 cGy h(-1), 1.7 cGy h(-1) and 2.6 cGy h(-1) respectively. Direct sunlight, fluorescent light and incandescent ambient lig...

Journal: :Physics in medicine and biology 2005
Martin J Butson Tsang Cheung Peter K N Yu

FWT-60 radiochromic film has been tested for colouration effects from fluorescent light sources and shown to produce a marked colouration when exposed to office fluorescent light sources showing an approximate 1 OD unit per 0.5 J m(-2) exposure to a broad ultraviolet (UV) UVA + UVB spectrum at the peak absorption wavelength. This produces a measurable and quantifiable response to UV exposure. B...

2017
Tomohiro Shimozato Yuichi Aoyama T. Shimozato Y. Aoyama

Purpose: The aim of this study was to develop a method for the direct measurement of electron beam width and distribution at the scattering foil on the carrousel in a medical linear accelerator gantry head, which differs from an existing indirect method for measuring the focal spot size using a camera or metallic slit located outside the gantry head. Methods: The electron beam emitted by the li...

2014
Richard E. Wendt

Radiochromic film with a dye incorporated into the radiation sensitive layer [Gafchromic EBT2, Ashland, Inc.] may be digitized by a color transparency scanner, digitally processed, and calibrated so that a digital image in units of radiation absorbed dose is obtained. A transformation from raw scanner values to dose values was developed based upon a principal component analysis of the optical d...