نتایج جستجو برای: removal torque
تعداد نتایج: 162806 فیلتر نتایج به سال:
This in vitro study evaluated the effect of mechanical cycling on the torque of retaining screw in external hexagon implants with platform switching (PS), regular platform (RP) and wide platform (WP). A total of 30 specimens were equally divided into 3 groups: PS, PR and WP. Each specimen was prepared with implants: 3.75 x 10 mm for RP group and 5.0x10 mm for PS and WP groups and its respective...
PURPOSE This study aimed to evaluate the correlation between microleakage and screw loosening at different types of implant-abutment connections and/or geometries measuring the torque values before and after the leakage tests. MATERIALS AND METHODS Three different abutment types (Intenal hex titanium, internal hex zirconium, morse tapered titaniuım) with different geometries were connected to...
INTRODUCTION Bisphosphonates have been shown to reduce osteoclastic activity and enhance pin fixation in both experimental and clinical studies. In this prospective, randomized study of high tibial osteotomy using the hemicallotasis (HCO) technique, we evaluate whether treatment by one single infusion of zoledronic acid can enhance the pin fixation. MATERIALS AND METHODS 46 consecutive patien...
high variability in delivering the target torque is reported for friction-style mechanical torque limiting devices (f-s mtlds). the effect of aging (number of use) on the accuracy of these devices is not clear. the purpose of this study was to assess the effect of aging on the accuracy (±10% of the target torque) of f-s mtlds.fifteen new f-s mtlds and their appropriate drivers from three differ...
This study aimed to measure the preload in different implant platform geometries based on micro-CT images. External hexagon (EH) implants and Morse Tapered (MT) implants (n=5) were used for the preload measurement. The abutment screws were scanned in micro-CT to obtain their virtual models, which were used to record their initial length. The abutments were screwed on the implant with a 20 Ncm t...
The aim of this study was to verify whether screw abutment lubrication can generate higher preload values compared to non-lubricated screws, a titanium abutment was screwed onto an implant analog and scanned with the Procera System to generate 20 zirconia abutments. MKIII Brånemark implants were clamped to a precision torque device, and the abutments were distributed in dry and wet groups with ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید