نتایج جستجو برای: retinal nerve fiber layer rnfl

تعداد نتایج: 618783  

2017
Xiang-Run Huang Robert W. Knighton Ye Z. Spector Jianzhong Qiao Wei Kong Qi Zhao

Purpose Glaucoma damages the retinal nerve fiber layer (RNFL). This study used precise multimodal image registration to investigate the changes of the RNFL reflectance spectrum and birefringence in nerve fiber bundles with different degrees of axonal damage. Methods The reflectance spectrum of individual nerve fiber bundles in normal rats and rats with experimental glaucoma was measured from ...

Journal: :Investigative ophthalmology & visual science 2006
Ichiro Kawaguchi Tomomi Higashide Shinji Ohkubo Hisashi Takeda Kazuhisa Sugiyama

PURPOSE To determine whether scanning laser ophthalmoscopy (SLO) is useful for in vivo imaging and quantitative evaluation of rat retinal nerve fiber layer (RNFL) using an optic nerve crush model. METHODS The optic nerve of the right eye was crushed intraorbitally with a clip. The left eye served as the untreated control. Fundus images of both eyes were recorded by SLO using an argon blue las...

2017
Divya Singh Sanjay K Mishra Esha Agarwal Reetika Sharma Shibal Bhartiya Tanuj Dada

INTRODUCTION To evaluate the relationship between retinal nerve fiber layer (RNFL) thickness measured by Cirrus high-definition (HD) optical coherence tomography (OCT) and the axial length and refractive error of the eye. MATERIALS AND METHODS A total of 100 eyes of 100 healthy subjects (age 20-34 years with M/F ratio of 57/43), comprising 50 eyes with emmetropia [spherical equivalent (SE) 0 ...

Journal: :Investigative ophthalmology & visual science 2009
Atsushi Nagata Tomomi Higashide Shinji Ohkubo Hisashi Takeda Kazuhisa Sugiyama

PURPOSE To determine whether optical coherence tomography (OCT) is useful for quantitative evaluation of the thickness of the rat retinal nerve fiber layer (RNFL) in an optic nerve crush model. METHODS An OCT system was developed with a modified commercial time-domain OCT and a superluminescent diode with a bandwidth of 150 nm. Optical components were optimized to acquire rat retinal images. ...

Akbarzadeh, Negar , Akbarzadeh, Siamak , Cheraghi, Zahra , Mazdeh, Mehrdokht ,

Background and Objective: In this study, the thickness of the retinal nerve fibers layer(RNFL) was compared among patients with mild cognitive impairment, Alzheimer's dementia, and healthy individuals (controls) using Optical Coherence Tomography (OCT) device. Materials and Methods: This case-control study was conducted on 30 patients diagnosed with mild cognitive impairment and 31 healthy sub...

Journal: :journal of current ophthalmology 0
حیدر امینی heidar amini علیرضا خدابنده alireza khodabande ساسان مقیمی sasan moghimi یداله اسلامی yadollah eslami رضا زارعی reza zarei قاسم فخرایی ghasem fakhraie

purpose: to quantify the intraobserver reproducibility of retinal nerve fiber layer (rnfl) measurements using scanning laser polarimetry with variable corneal compensation in glaucoma suspect patients. methods: twenty-six eyes of 26 glaucoma suspect patients were included. complete ophthalmologic examination and standard automated perimetry were performed for all of them. rnfl measurements were...

2017
Christoph Nützi Andreas Schötzau Matthias C Grieshaber

PURPOSE To evaluate clinically activated retinal astrocytes and Müller cells (ARAM) regarding retinal sensitivity and retinal nerve fiber layer (RNFL) thickness in primary open-angle glaucoma (POAG). METHODS Central visual field (VF; i.e., retinal sensitivity) was measured with a custom-made macular pattern by microperimetry and correlated with the presence (ARAM+) or absence (ARAM-) of ARAM ...

2017
Yantao Wei Hong Jiang Yingying Shi Dongyi Qu Giovanni Gregori Fang Zheng Tatjana Rundek Jianhua Wang

Purpose To characterize age-related alterations in the retinal microcirculation, microvascular network, and microstructure in healthy subjects. Methods Seventy-four healthy subjects aged from 18 to 82 years were recruited and divided into four age groups (G1 with age <35 years, G2 with age 35 ∼ 49 years, G3 with age 50 ∼ 64 years, and G4 with age ≥65 years). Custom ultra-high resolution optic...

2016
Tomomi Higashide Shinji Ohkubo Masanori Hangai Yasuki Ito Noriaki Shimada Kyoko Ohno-Matsui Hiroko Terasaki Kazuhisa Sugiyama Paul Chew Kenneth K. W. Li Nagahisa Yoshimura Alfred S Lewin

PURPOSE To identify the factors which significantly contribute to the thickness variabilities in macular retinal layers measured by optical coherence tomography with or without magnification correction of analytical areas in normal subjects. METHODS The thickness of retinal layers {retinal nerve fiber layer (RNFL), ganglion cell layer plus inner plexiform layer (GCLIPL), RNFL plus GCLIPL (gan...

2014
David A Belyea Rashed N Alhabshan Sankaranarayana P Mahesh Gregory S Gertner Mirsad M Ibisevic Abdullah S Habib Jacob A Dan

CONTEXT Although Heidelberg retinal tomography (HRT)-generated topographic images have been studied extensively for the detection of retinal nerve fiber layer (RNFL) defects, little is known about the role of HRT-generated surface reflectivity images in the detection of RNFL defects in either patients with glaucoma or glaucoma suspects. AIMS To evaluate the effectiveness of HRT version II (HR...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید