نتایج جستجو برای: septal occluder device
تعداد نتایج: 705866 فیلتر نتایج به سال:
The isolated perimembranous ventricular septal defect is one of the most common congenital cardiac malformations. Although surgery has been performed and has a low associated risk, it still involves morbidity due to factors such as residual leaks, atrioventricular block, postpericardiotomy syndrome and arrhythmias. It has been speculated that percutaneous closure of these defects could minimize...
Atrial septal defect (ASD) is a congenital heart defect that is being increasingly treated using percutaneous interventions. However, these techniques are not devoid of complications. One such complication is device embolization. Removal of such closure device poses tremendous risk and consequent complications both by percutaneous retrieval and surgical removal. Herein, we present two cases of ...
Percutaneous atrial septal defect closure is routinely performed nowadays because of the ease of implantation as well as the low complication rate. The Atriasept ASD occluder is a low profile, double disc device; over the years several modifications have been made. We report two cases of aortic sinus perforation by the Atriasept ASD occluder (model 2007). Two asymptomatic patients, in whom the ...
Inroduction: This study reports on our experience with transcatheter closure of perimembraneous ventricular septal defects (pm-VSDs) with Amplatzer duct occluder I (ADO I) and Amplatzer duct occluder II (ADO II) Methods: Transcatheter device implantation with ADO I and ADO II was attempted in 17 patients with pm-VSD between August 2014 to December 2015. We usually decided the appropriate type a...
Case: A 36 year-old woman without significant past medical history was admitted with left-sided hemiparesis. Imaging studies confirmed a right middle cerebral artery (MCA) stroke with normal carotid arteries. Transesophageal echocardiogram (TEE) showed right heart enlargement and a large secundum atrial septal defect (ASD) (Figure 1). Using TEE guidance, an ASD occluder device was placed withou...
Forty patients were catheterized for closure of atrial septal defects with the Rashkind patent ductus arteriosus umbrella device, a modified Rashkind umbrella device, and the newly designed Lock Clamshell Occluder. Patients weighed 8 kg or more (a requirement for transvenous access with the 11F delivery sheath) and had defects suitable for closure based on two-dimensional echocardiography. The ...
Cardiac perforation after device closure of atrial septal defects with the Amplatzer septal occluder
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید