نتایج جستجو برای: source parameters

تعداد نتایج: 970760  

Journal: :iranian journal of radiation research 0
m. yazdani department of physics, tarbiat moallem university of sabzevar, sabzevar, iran a.a. mowlavi department of physics, tarbiat moallem university of sabzevar, sabzevar, iran

background: monte carlo determination of tg-43 brachytherapy dosimetry parameters and dose distribution calculation for 131cs source model cs-1 are presented in this study. materials and methods: the dose distribution was calculated around the 131cs model cs-1 located in the center of 30 cm ×30 cm ×30 cm water, and soft tissue phantoms cube using mcnp code by monte carlo method. the percentage ...

2004
M. Dovčiak

The effects of strong gravity on the polarization of the Compton reflection from an X-ray illuminated accretion disc are studied. The gravitational field of a rotating black hole influences Stokes parameters of the radiation along the propagation to a distant observer. Assuming the lamp-post model, the degree and the angle of polarization are examined as functions of the observer’s inclination ...

2015
A. R. Milani M. Tarafdar Hagh B. Mozafari B. Asadzadeh

This paper presents a new methodology to estimate harmonic sources in a distribution network, based on measurements of limited number of given buses. The algorithm utilizes independent component analysis (ICA), a method of solving blind source separation theory. In this method, pseudo impedance matrix of distribution network is estimated. The location of harmonic sources will be identified by e...

2014
D. H. Boteler R. J. Pirjola

Assessing the geomagnetic hazard to power systems requires reliable modelling of the geomagnetically induced currents (GIC) produced in the power network. This paper compares the Nodal Admittance Matrix method with the Lehtinen–Pirjola method and shows them to be mathematically equivalent. GIC calculation using the Nodal Admittance Matrix method involves three steps: (1) using the voltage sourc...

Journal: :EURASIP J. Adv. Sig. Proc. 2007
Thomas Melia Scott T. Rickard

The DUET blind source separation algorithm can demix an arbitrary number of speech signals usingM = 2 anechoic mixtures of the signals. DUET however is limited in that it relies upon source signals which are mixed in an anechoic environment and which are sufficiently sparse such that it is assumed that only one source is active at a given time frequency point. The DUET-ESPRIT (DESPRIT) blind so...

Journal: :iranian journal of radiation research 0
m. zehtabian radiation research center and radiation medicine department, school of engineering, shiraz university, shiraz, iran r. faghihi radiation research center and radiation medicine department, school of engineering, shiraz university, shiraz, iran s. sina radiation research center and radiation medicine department, school of engineering, shiraz university, shiraz, iran

background: iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. dosimetric parameters of brachytherapy sources should be determined according to aapm tg-43u1 recommendations before clinical use. monte carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. materials and methods: dosimetric parameters (dos...

Journal: :CoRR 2015
Maruti Kumar Mudunuru K. B. Nakshatrala

This paper concerns with mesh restrictions that are needed to satisfy several important mathematical properties – maximum principles, comparison principles, and the non-negative constraint – for a general linear second-order elliptic partial differential equation. We critically review some recent developments in the field of discrete maximum principles, derive new results, and discuss some poss...

ژورنال: سنجش و ایمنی پرتو 2019

Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated are placed as close as possible to the tumor site inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule. Hereby, in this paper, dosimetric parameters of I-125 brachytherapy source model 6711 are estimated accordin...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید