Journal: :Thrombosis and haemostasis 2010
Jose Ramon Gonzalez-Porras Francisco Martin-Herrero Tomas J Gonzalez-Lopez Juan Olazabal María Diez-Campelo Pedro Pabon Ignacio Alberca Jesus F San Miguel

Dear Sir, Activated platelets play a crucial role in the pathogenesis of acute coronary syndrome (ACS) (1), and platelet size can be a determinant of platelet function. Thus, large platelets are metabolically more active than small platelets and have greater pro-thrombotic potential (2). However, the clinical influence of platelet size, measured as mean platelet volume (MPV), is controversial (...

2017
Gebremedhin Gebremicael Yohanes Belay Fitsum Girma Yemane Abreha Atsbeha Gebreegziabxier Simret Tesfaye Zelalem Messele Yibeltal Assefa Bahrie Bellete Desta Kassa Lara Vojnov

INTRODUCTION In Ethiopia, CD4+ T-cell counting is still required for all patients at baseline before antiretroviral therapy (ART) and to determine eligibility and follow-up of opportunistic infection prophylaxis. However, access to CD4+ T cell count in rural health facilities remains a major challenge in Ethiopia like other resource-limited settings. METHODOLOGY Both capillary and venous bloo...

Journal: :Journal of clinical pathology 1969
T R Lappin A Lamont M G Nelson

The Technicon AutoAnalyzer SMA-4 has been systematically evaluated. Carry-over from the sample cups was found to be within an acceptable range. The precision and accuracy of the four parameters determined by the instrument have been investigated. The haemoglobin results were found to be accurate. There was good agreement with leucocyte counts performed on the model A Coulter electronic cell cou...

Journal: :Clinical chemistry 1975
J C Black W B Furman

We describe a rapid method for calibrating the Technicon AutoAnalyzer colorimeter I. Test solutions of bromphenol blue are recommended for the calibration, in preference to solutions of potassium dichromate, based on considerations of the instrument's working range and of the stray light characteristics of the associated filters.

Journal: :Clinical chemistry 1980
E R Dalferes L S Webber B Radhakrishnamurthy G S Berenson

We describe a procedure for determining thiocyanate in plasma with a Technicon AutoAnalyzer I, modified with a 50-mm tubular flow cell to increase the sensitivity of thiocyanate detection. The procedure is suitable for distinguishing cigarette smokers from non-smokers, the mean for smokers being 151 (SD 43) micromol/L and for non-smokers 62 (SD 19) micromol/L.

Journal: :Journal of clinical pathology 1974
B B Bauminger

A sensitive micro method for the manual estimation of true glucose in 10 mul plasma by an enzymatic technique is described. Protein precipitation is avoided. The method is simple to perform, accurate and precise. Agreement with a glucose oxidase autoanalyzer method is excellent, even with haemolysed and icteric specimens.

Journal: :The Annals of Clinical and Analytical Medicine 2019