نتایج جستجو برای: the ventilator artificial

تعداد نتایج: 16088116  

Journal: :Archives of disease in childhood 1985
D Field A D Milner I E Hopkin

Twenty two babies receiving artificial ventilator support were studied on 29 occasions to determine the effects of low levels of positive end expiratory pressure. Mean positive end expiratory pressure during these studies was 2.6 cm H2O. Changes in tidal volume, minute volume, compliance, and transcutaneous gas trends produced by the use of positive end expiratory pressure were investigated. Po...

2010
Peter Betit

Extracorporeal membrane oxygenation (ECMO) is a form of cardiopulmonary bypass adapted for long-term use. Blood is drained from the patient, pumped through an artificial lung or membrane where gas exchange is augmented, and then re-infused back to the patient. ECMO provides support for the neonate with severe respiratory failure so that potentially deleterious ventilator settings can be minimiz...

Journal: :The European respiratory journal 2001
A Torres J Carlet

Clinical diagnosis of ventilator-associated pneumonia . . . . . . . . . . . . . . . . . . . . . . . . . . 1034 Bacteriological and histological aspects of ventilator-associated pneumonia . . . . . . . . . . . . 1035 Aetiology of ventilator-associated pneumonia . . . . . . . . . . . . . . . . . . . . . . . . . . 1036 Diagnostic techniques for ventilator-associated pneumonia . . . . . . . . . . ....

2018
Ya-Chi Li Hui-Ling Lin Fang-Chun Liao Sing-Siang Wang Hsiu-Chu Chang Hung-Fu Hsu Sue-Hsien Chen Gwo-Hwa Wan

BACKGROUND Few studies have investigated the difference in bacterial contamination between conventional reused ventilator systems and disposable closed ventilator-suction systems. The aim of this study was to investigate the bacterial contamination rates of the reused and disposable ventilator systems, and the association between system disconnection and bacterial contamination of ventilator sy...

Journal: :Computation (Basel) 2022

Early prediction of mortality and risk deterioration in COVID-19 patients can reduce increase the opportunity for better more timely treatment. In current study, DL model explainable artificial intelligence (EAI) were combined to identify impact certain attributes on ventilatory support patients. Nevertheless, does not suffer from curse dimensionality, but order significant attributes, EAI feat...

Journal: :Respiratory care 2016
Ariel M Modrykamien Lori Killian Ryan W Walters

BACKGROUND The utilization of checklists, bundles, and protocols attempts to provide standardization in the delivery of patient care. Despite important progress obtained in the prevention of hospital-acquired infections, the daily management of mechanical ventilation is still prone to heterogeneity, depending on the number of providers manipulating the ventilator. Whether the number of changes ...

Journal: :iranian journal of medical sciences 0
vikram mohan department of physiotherapy, faculty of health sciences, universiti teknologi mara, puncak alam, selangor, malaysia asiah m hashim department of physiotherapy, hospital kuala lumpur, kuala lumpur, malaysia leonard h joseph physiotherapy program, faculty of allied health sciences, universiti kebangsaan malaysia, kuala lumpur, malaysia juleida embong department of physiotherapy, hospital kuala lumpur, kuala lumpur, malaysia zalila kasim department of physiotherapy, hospital kuala lumpur, kuala lumpur, malaysia

patients who are on prolonged ventilator support in critical care unit present wide variety of complications, which range from reduction in oxygen uptake to various musculoskeletal impair-ments. early mobilization and rehabilitation are encouraged to manage these complications effectively. use of tilt table to motivate early mobilization in the intensive care unit for ventilator practices is no...

Journal: :Critical Care 1999
Giorgio A Iotti Maddalena C Olivei Antonio Braschi

Although they represent a valuable alternative to heated humidifiers, artificial noses have unfavourable mechanical effects. Most important of these is the increase in dead space, with consequent increase in the ventilation requirement. Also, artificial noses increase the inspiratory and expiratory resistance of the apparatus, and may mildly increase intrinsic positive end-expiratory pressure. ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید