نتایج جستجو برای: thermoluminescence dosimeters tld

تعداد نتایج: 3413  

2011
Pooneh Saidi Mahdi Sadeghi S. Hamed Hosseini Claudio Tenreiro

This work presents experimental dosimetry results for a new 103Pd brachytherapy seed, in accordance with the AAPM TG-43U1 recommendation that all new low-energy interstitial brachytherapy seeds should undergo one Monte Carlo (MC) and at least one experimental dosimetry characterization. Measurements were performed using TLD-GR200A circular chip dosimeters using standard methods employing thermo...

2009
F M Gagliardi K J Roxby P E Engström J C Crosbie

Complex intensity-modulated radiation therapy (IMRT) treatment plans require rigorous quality assurance tests. The aim of this study was to independently verify the delivered dose inside the patient in the region of the treatment site. A flexible naso-gastric tube containing thermoluminescent dosimeters (TLDs) was inserted into the oesophagus via the sinus cavity before the patient’s first trea...

Journal: :Applied sciences 2023

This study aimed to evaluate radiation doses from handheld X-ray devices, specifically NOMAD Pro 2TM (DvcN), Rextar X (DvcRX), and Diox 602 (DvcD), targeting operator patient’s critical organs tissues. Calibrated TLD-100H dosimeters were placed on a mannequin phantom head, focusing the eyes, thyroid, gonads, hands, salivary glands. Using TLD reader, absorbed equivalent post irradiation assessed...

2014
F. MIHAI A. STOCHIOIU

The response of the passive photodosimeter with halide film characterized by a high optical density of about 0.550 ± 0.007 was analysed on dose ranges, taking into consideration the filters of the dosimetric badge, and finally compared with the thermoluminescent dosimeter (TLD). In this respect the dosimeters were exposed to a Cs 137 calibration radioactive source at different points within (0....

2014
Adem Un Ibrahim Han

Mass energy absorption coefficients and effective atomic numbers for photon energy absorption, ZPEAeff have been calculated in the energy range from 1 keV to 20 MeV for human tissues, Adipose Tissue, Blood Whole, Bone Cortical, Brain Grey/White Matter, Breast Tissue, Eye Lens, Lung Tissue, Muscle Skeletal, Ovary, Testis, Soft Tissue. Mass energy absorption coefficients and effective atomic numb...

2015
Priscila do Carmo Santana Paulo Marcio Campos de Oliveira Marcelo Mamede Mariana de Castro Silveira Polyanna Aguiar Raphaela Vila Real Teógenes Augusto da Silva

OBJECTIVE To evaluate the level of ambient radiation in a PET/CT center. MATERIALS AND METHODS Previously selected and calibrated TLD-100H thermoluminescent dosimeters were utilized to measure room radiation levels. During 32 days, the detectors were placed in several strategically selected points inside the PET/CT center and in adjacent buildings. After the exposure period the dosimeters wer...

SM Hosseini Pooya, T Orouji

Background: The accurate results of the individual doses in personal dosimety which are reported by the service providers in personal dosimetry are very important. There are national / international criteria for acceptable dosimetry system performance.Objective: In this research, the sources of uncertainties are identified, measured and calculated in a personal dosimetry system by TLD.Method: T...

2012
A. Di Fulvio S. O. Souza R. Ciolini J. Esposito P. Colautti F. d’Errico

The application of ionizing radiations in different fields requires the use of equipment capable of detecting their presence or quantifying them. Detectors of the most different shapes, composition and characteristics are required to cover the full range of application of ionizing radiations. At present, thermoluminescent detectors (TLD) are the most widely employed for individual gamma monitor...

Journal: :Advances in space research : the official journal of the Committee on Space Research 1995
G Reitz W Atwell R Beaujean J W Kern

Detector packages were exposed on the European Retrievable Carrier (EURECA) as part of the Biostack experiment inside the Exobiology and Radiation Assembly (ERA) and at several locations around EURECA. The packages consist of different plastic nuclear track detectors, nuclear emulsions and thermoluminescence dosimeters (TLDs). Evaluation of these detectors yields data on absorbed dose and parti...

2006
M. Rębisz B. Voss E. Usenko A. Heinz M. Pomorski E. Berdermann

In this paper we report on first results obtained using polycrystalline CVD diamond detectors irradiated with heavily ionizing particles at GSI. At the UNILAC accelerator, ions with energies near the Bragg-Peak have been stopped inside the material whereas at the heavy-ion therapy facility of GSI these detectors are operated in transmission mode and have been studied in a carbon beam from SIS w...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید