F Shahedi, H Gholamhosseinian M H Bahreyni M Mohammadi, M Momennezhad, R Salek, S Bayani, S M Hashemi, S Nasseri

Background: The present study aimed to introduce a rapid transmission dosimetry through an electronic portal-imaging device (EPID) to achieve two-dimensional (2D) dose distribution for homogenous environments. Material and Methods: In this Phantom study, first, the EPID calibration curve and correction coefficients for field size were obtained from EPID and ionization chamber. Second, the...

2016
Marije Baan Hashini Nilushika Galappaththi-Arachchige Silindile Gagai Christine G. Aurlund Birgitte J. Vennervald Myra Taylor Lisette van Lieshout Eyrun F. Kjetland

BACKGROUND More than 260 million people live with schistosomiasis and regular mass-treatment should be implemented to prevent morbidity. Praziquantel, dosed at 40 milligrams per kilogram bodyweight, is the drug of choice. During the last decades the WHO Tablet Pole-which estimates tablet need by height as representing weight-has been used as a practical and cheap tool in mass treatment. In Sout...

Objective(s): To investigate and compare quantitative accuracy of kidney absorbed dose measures made from both 2D and 3D imaging in patients receiving 177LuDOTATATE (Lutate) for treatment of neuroendocrine tumours (NETs). Methods: Patients receiving Lutate therapy underwent both whole body planar imaging and SPECT/CT imaging over the kidneys at time points 0.5, 4, 24, and 96-120 hours after inj...

Journal: :iranian journal of medical physics 0
reza faghihi school of mechanical engineering, nuclear engineering department, shiraz university, shiraz, iran radiation research center, shiraz university, shiraz, iran

introduction after the publication of task group number 43 dose calculation formalism by the american association of physicists in medicine (aapm), this method has been known as the most common dose calculation method in brachytherapy treatment planning. in this formalism, the water phantom is introduced as the reference dosimetry phantom, while the attenuation coefficient of the sources in the...

M. Amoui, M. Hosntalab, M.R. Teimoori Sichani, Sh. Akhlaghpoor,

Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...

Ali Soleymani Meigooni Reza Faghihi, Sedigheh Sina

Introduction After the publication of Task Group number 43 dose calculation formalism by the American Association of Physicists in Medicine (AAPM), this method has been known as the most common dose calculation method in brachytherapy treatment planning. In this formalism, the water phantom is introduced as the reference dosimetry phantom, while the attenuation coefficient of the sources in the...

Journal: :Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 2001
M Engelsman E M Damen P W Koken A A van 't Veld K M van Ingen B J Mijnheer

BACKGROUND AND PURPOSE Conformal radiotherapy requires accurate dose calculation at the dose specification point, at other points in the planning target volume (PTV) and in organs at risk. To assess the limitations of treatment planning of lung tumours, errors in dose values, calculated by some simple tissue inhomogeneity correction algorithms available in a number of currently applied treatmen...

2016
Nicolle Dunkerley Frederick R Bartlett Anna M Kirby Philip M Evans Ellen M Donovan

OBJECTIVE The purpose of the work was to estimate the dose received by the heart throughout a course of breath-holding breast radiotherapy. METHODS 113 cone-beam CT (CBCT) scans were acquired for 20 patients treated within the HeartSpare 1A study, in which both an active breathing control (ABC) device and a voluntary breath-hold (VBH) method were used. Predicted mean heart doses were obtained...

2014
Guang-shun Zhang Shao-min Huang Cui Chen Sen-kui Xu Dan-dan Zhang Xiao-wu Deng

An approximate correction method for the CT value-electron density curve of CBCT was established, through comparison and fitting with FBCT images, and applied to evaluate the therapeutic dose of IMRT. The precision of using CBCT for plan calculation was validated by comparing the dose distribution between CBCT- and FBCT-based IMRT plans. Also setup deviations were simulated to evaluate the abil...

Journal: :Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 2012
Emma J Harris Ellen M Donovan Charlotte E Coles Hans C J de Boer Andrew Poynter Christine Rawlings Gordon C Wishart Philip M Evans

PURPOSE This study investigates (i) the effect of verification protocols on treatment accuracy and PTV margins for partial breast and boost breast radiotherapy with short fractionation schema (15 fractions), (ii) the effect of deformation of the excision cavity (EC) on PTV margin size, (iii) the imaging dose required to achieve specific PTV margins. METHODS AND MATERIALS Verification images u...