نتایج جستجو برای: treatment planning system tps

تعداد نتایج: 3600267  

 شهروز غفوری, , عباس میرشفیعی, , عبدالفتاح صراف نژاد, , علیرضا صالحی نوده, , محمد حسین علیمحمدیان, ,

Background: TPS is one of the tumor markers which has specially been considered due to its exclusive physiological characteristics like its easy measurement in serum of cancer patients. This study has been due to evaluate the efficiency of this tumor marker in the prognosis, treatment control and follow up of patients with gastrointestinal cancers including esophagus, stomach and colorectal. M...

Journal: :Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics 2014
Caroline Lafond Frédéric Gassa Christophe Odin Gaël Dréan Justine Even Renaud De Crevoisier Pascal Pommier Jean-Pierre Manens Marie-Claude Biston

PURPOSE To investigate the performances of two commercial treatment planning systems (TPS) for Volumetric Modulated Arc Therapy (VMAT) optimization regarding prostate cancer. The TPS were compared in terms of dose distributions, treatment delivery parameters and quality control results. MATERIALS AND METHODS For ten patients, two VMAT plans were generated: one with Monaco TPS (Elekta) and one...

2018
Dae-Hyun Kim Sungkoo Cho Kwanghyun Jo EunHyuk Shin Chae-Seon Hong Youngyih Han Tae-Suk Suh Do Hoon Lim Doo Ho Choi

In particle radiotherapy, range uncertainty is an important issue that needs to be overcome. Because high-dose conformality can be achieved using a particle beam, a small uncertainty can affect tumor control or cause normal-tissue complications. From this perspective, the treatment planning system (TPS) must be accurate. However, there is a well-known inaccuracy regarding dose computation in he...

2009
John P. Gibbons Koren Smith Dennis Cheek Isaac Rosen

A new calculation algorithm has been developed for independently verifying doses calculated by the TomoTherapy Hi.Art treatment planning system (TPS). The algorithm is designed to confirm the dose to a point in a high dose, low dose-gradient region. Patient data used by the algorithm include the radiological depth to the point for each projection angle and the treatment sinogram file controllin...

Journal: :Physics in medicine and biology 2003
Elinore Wieslander Tommy Knöös

An increasing number of patients receiving radiation therapy have metallic implants such as hip prostheses. Therefore, beams are normally set up to avoid irradiation through the implant; however, this cannot always be accomplished. In such situations, knowledge of the accuracy of the used treatment planning system (TPS) is required. Two algorithms, the pencil beam (PB) and the collapsed cone (C...

Journal: :The journal of breast health 2014
Melis Gültekin Mehmet Karabuğa Ferah Yıldız Gökhan Özyiğit Mustafa Cengiz Faruk Zorlu Fadıl Akyol Murat Gürkaynak

OBJECTIVE The aim of this study was to find the most appropriate technique for postmastectomy chest wall (CW) and lymphatic irradiation. MATERIALS AND METHODS Partially wide tangent, 30/70 photon/electron mix, 20/80 photon/electron mix and CW and internal mammary en face electron field, were studied on computerized tomography (CT) scans of 10 left breast carcinoma patients and dosimetric calc...

Ahmadreza Sebzari Fathollah Bouzarjomehri Kaveh Shirani Tak Abi Malihe Rezaie Yazdi Maryam Rezaie Yazdi Narges Kheirollahi Payam Izadpanahi

Introduction: The functionality and quality of any treatment planning system (TPS) strongly depends on the type of Algorithm which is used by it. Obviously, the role of dose distribution algorithms in calculation of prescribed dose inside the tumor in modern radiotherapy techniques has more important than past to achieve the best clinical outcomes, especially in tumors which ar...

2012
Harish K Malhotra Vincent Wu Zhou Wang Sachin Patil

PURPOSE Standard treatment plan libraries are often used to ensure a quick turn-around time for vaginal cylinder treatments. Recently there is increasing interest in transitioning from conventional 2D radiograph based brachytherapy to 3D image based brachytherapy, which has resulted in a substantial increase in treatment planning time and decrease in patient through-put. We describe a novel tec...

2013
B. Allgaier E. Schüle J. Würfel

Intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) are state-of-the-art irradiation techniques for the delivery of highly conformal radiation fields to the target volume. These techniques require complex treatment planning system (TPS) algorithms as well as sophisticated irradiation methods. As a result, the use of quality assurance tools for the verificati...

Journal: :iranian journal of radiation research 0
m.n. anjum mcgill university health centre l5-112, 1650-cedar avenue, montreal general hospital, canada h3g 1a4 w. parker mcgill university health centre l5-112, 1650-cedar avenue, montreal general hospital, canada h3g 1a4 i. aldahlawi mcgill university health centre l5-112, 1650-cedar avenue, montreal general hospital, canada h3g 1a4 r. ruo mcgill university health centre l5-112, 1650-cedar avenue, montreal general hospital, canada h3g 1a4 m. afzal department of physics, the islamia university of bahawalpur, pakistan

background: we have validated the monitor unit calculations from a commercially available treatment planning system (tps) for three intensity modulated radiotherapy (imrt) planning techniques for tangential breast irradiation by using ionization chamber measurements. materials and methods: treatment plans were generated for forty-two breast patients by a forward planned field in field technique...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید