نتایج جستجو برای: آشکارساز hpge

تعداد نتایج: 1884  

Journal: :Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2021

2013
Fedja Kadribasic

The Cryogenic Dark Matter Search (CDMS) is an experiment to directly detect dark matter, a mysterious substance that makes up the majority of the matter content in the Universe and has so far only been observed due to its gravitational effects. CDMS uses high-purity Ge (HPGe) crystals as detectors for dark matter in the form of weakly interacting massive particles (WIMP). In order to reduce sys...

Journal: :Journal of physics 2022

Abstract A standard procedure for characterizing the high-purity germanium detector (HPGe), manufactured by Canberra Industries Inc [1], is performed directly company using patented methods. However, usually expensive and must be repeated because characteristics of HPGe crystal change over time. In this work, principles a technique are developed use in obtaining optimizing based on cost-effecti...

2008
ChengDong Fu Xiaohu Mo N.Yu. Muchnoi Qing Qin Huamin Qu Yifang Wang Jinqiang Xu

This document contains a proposal of the BEPC-II collider beam energy calibration system (IHEP, Beijing). The system is based on Compton backscattering of carbon dioxide laser radiation, producing a beam of high energy photons. Their energy spectrum is then accurately measured by HPGe detector. The high-energy spectrum edge will allow to determine the average electron or positron beam energy ε ...

2008
Katarzyna Szymańska

One of the goals of hypernuclear physics is to study the properties of baryon-baryon interaction including the strangeness contribution. Double hypernuclei can provide information about the ΛΛ interaction in addition to the hyperon-hyperon and hyperon-nucleus one. A new technique for producing double hypernuclei using antiprotons is foreseen in the PANDA experiment at FAIR. Gamma ray spectrosco...

2017
B. Rossé O. Stezowski

The EXOGAM clover detector consists of four high-purity germanium (HPGe) crystals in a common cryostat. Each individual crystal is electrically segmented into four regions. We propose a method based on a multidimensional fitting procedure to calibrate the energy from the segments. This method could be used for any kind of segmented germanium detector. Its application to the EXOGAM clover is dis...

ژورنال: سنجش و ایمنی پرتو 2020

High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector syst...

2011
M. A. SAIZU M. R. CALIN

Because of the major impact of the radioactive materials on the environment, their characterization methods have to be well defined, complete and agreed by the control bodies and the civil society. The paper presents measurements of certified etalon gamma emitting radiation sources, in order to perform the energy and the efficiency calibration of a new HPGe spectrometric system, and to determin...

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2002
J C Hardy V E Iacob M Sanchez-Vega R T Effinger P Lipnik V E Mayes D K Willis R G Helmer

With the goal of measuring precise gamma-ray intensities for short-lived (< 5 s) accelerator-produced activities, we have calibrated the efficiency of an HPGe detector between 53 and 1836keV to sub-percent precision with a combination of source measurements and Monte Carlo calculations. Using known or independently measured detector dimensions, we have achieved both relative and absolute agreem...

ژورنال: :مکانیک سازه ها و شاره ها 0
حسن عبداللهی استادیار برق-الکترونیک، دانشکده برق، دانشگاه علوم و فنون هوایی شهید ستاری فاطمه سمائی فر دانشجوی دکتری برق- الکترونیک، دانشگاه صنعتی مالک اشتر افسانه حق نگهدار کارشناس ارشد برق– الکترونیک، دانش آموخته دانشگاه علم و صنعت ایران

در این مقاله، آشکارساز مادون قرمز میکروکانتیلیور با حساسیت بالا و بدون نیاز به خنک ساز، طراحی و شبیه­سازی شده است. این آشکارساز شامل، ناحیه جاذب، نواحی دو ماده ای و ایزوله و ستون­های نگه­دارنده است. ساختار آن معلق و به صورت دو لایه­ای از جنس دی اکسید سیلیکون (sio2) به ضخامت µm1 و آلومینیوم (al) به ضخامت nm200 است. در این آشکارساز، میزان جذب ir و میزان خمش با طراحی ناحیه جاذب به صورت دو ماده ای ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید