نتایج جستجو برای: air conditioning and room temperature good
تعداد نتایج: 16971543 فیلتر نتایج به سال:
In case of energy storage air conditioning system, due to load fluctuation, the traditional control methods can't obtain good effect, the model predictive control method can realize the optimization control system, and can overcome the influence of load fluctuation. In order to realize the predictive control, need to study model of air conditioning system. Ice storage air-conditioning system, b...
A look at today’s construction models in rural architectures shows that rural houses are being built based on urban housing models and many aspects including climatic issues and natural ventilation are being ignored. Implementation of urban standards for rural housing is not considered suitable and housing models in villages must be revised according to the the current needs of each region. Des...
In a cardiac procedure room, ventilated by a ventilation and air-conditioning system with turbulent mixed airflow, a protection zone in the operating area could be defined through visualization of airflows. Within this protection zone, no turbulence was detectable in the room air.Under the given conditions, disinfection of all surfaces including all furniture and equipment after the last operat...
This research examines the benefits of designing a living space in a basement, as a method of passive temperature control in summer, combined with thermal ceramic panels (TCP) on some walls. These panels incorporate a capillary system of polypropylene tubes which work with cold water. We studied a detached house on the coast of Alicante, where the moderate temperature of the ground tempered int...
This work investigated the autogenous healing of interface bond between hollow natural fiber (HNF) (e.g., sisal fiber) and reactive magnesium cement (RMC). Preloading -reloading test was conducted to single embedded specimens, results suggested that can be improved by over 300% after wetting-air cycles conditioning, hot water conditioning demonstrated greater efficiency compared room temperatur...
This thesis investigates the problem of regulating the temperature of a conditioned space using a Solar Assisted Air Conditioning Systems (SAACS) prototype located at Cabo Rojo, Puerto Rico. The SAACS Prototype consists of a 66 flat plate solar collector array with 115.4 m 2 of selective surface area, a 35 kW single-effect lithium-bromide absorption chiller, a 84 kW cooling tower, a 50 kW auxil...
• Room temperature sensors were compared to air and globe sensors. The assumption of measured type affected sensor performance the most. Conventional wired close operative temperature. Wireless varied in their sensitivity radiation depending on casing. Deviations from reference smaller radiant system cases. Thermostats control heating, ventilation air-conditioning (HVAC) a building based they m...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید