نتایج جستجو برای: amplatzer
تعداد نتایج: 1200 فیلتر نتایج به سال:
Atrial septal defect (ASD) is one of the most common types congenital heart defects. Percutaneous closure ASD relatively safe and accepted as an alternative to surgery. However, device-related complications can occur rarely. Embolization Amplatzer atrial occluder (ASO) major complication percutaneous device closure. The author presents a case early embolization ASO into left atrium, which remov...
Two children (a 9 year old boy and a 2.5 year old girl) with coronary artery fistulae communicating with the right ventricle underwent successful transcatheter occlusion using an antegrade technique. A Rashkind double umbrella device was used in one case and an Amplatzer duct occluder in the other.
We describe a case of a 46-year-old woman with dehiscence and paravalvular leak of a second-time replaced mitral mechanical prosthesis, successfully treated with Amplatzer occlusion of the paravalvular leak, thus avoiding a second reoperation and improving the patient's symptoms.
Herein, we are presenting a case of persistent interatrial septal defect diagnosed during coronary artery bypass grafting (CABG). Twice, attempts had been made to close this shunt using amplatzer septal occlude. However, percutaneous technique had failed in both occasions. The patient presented with chest pain 4 years after the second attempt and required urgent CABG. Persistent shunt was repai...
Lutembacher's syndrome is a rare combination of atrial septal defect (ASD) and rheumatic mitral stenosis. Traditionally, this condition is treated surgically. We present a case of Lutembacher's syndrome that was successfully treated with percutaneous transcatheter mitral commissurotomy (PTMC) using the Inoue balloon. Closure of ASD was successfully achieved with an Amplatzer atrial septal occlu...
We report the case of a young girl with a mixed total anomalous pulmonary venous return (cardiac and supracardiac) treated sequentially by partial neonatal surgery, and then catheterization at age 19 with installation of an Amplatzer device as a treatment of the remaining anomaly. We describe the usefulness of magnetic resonance imaging in both the diagnosis and follow-up of this anomaly.
Embolization of the closure device is a rare but potentially fatal complication of percutaneous atrial septal defect (ASD) closure. We report a case of 45-year-old woman who underwent ASD device closure with 32 mm Amplatzer device, which was embolized to the pulmonary artery without symptom one day after successful device implantation.
INTRODUCTION The device closure of atrial septal defects has evolved over the years. In the early days of transcatheter occlusion, balloon sizing was used to choose an appropriate sized device. We postulate that balloon sizing does not value-add to the procedure and is unnecessary. MATERIALS AND METHODS Patients who had balloon sizing, with (Group 1, n = 38) or without (Group 2, n = 21) atria...
OBJECTIVES This study reports our clinical experience with transcatheter closure of secundum atrial septal defects (ASDs) in children, using the Amplatzer, a new occlusion device. BACKGROUND None of the devices previously used for transcatheter closure of interatrial communications has gained wide acceptance. METHODS We examined the efficacy and safety of the Amplatzer, a new self-centering...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید