نتایج جستجو برای: aspheric intraocular lens
تعداد نتایج: 64758 فیلتر نتایج به سال:
purpose: to describe a case with a rare complication of posterior chamber intraocular lens (pc-iol) implantation in a patient who had undergone extracapsular cataract extraction (ecce) two years before case report: a 80-year-old diabetic woman presented with an exposed pc-iol in her left eye with a history of mechanical trauma. slit-lamp examination revealed an extruded pc-iol lied on the anter...
purpose : to evaluate the near visual performance of an accommodative intraocular lens (iol) tetraflex, in comparison to a standard monofocal foldable iol in cataract surgery. setting: eye research center , farabi eye hospital , department of ophthalmology, tehran university of medical sciences, iran . methods : forty six eyes of 23 patients with cataract underwent phacoemulsification and accom...
PURPOSE To describe the clinical performance of a new dual-optic intraocular lens (IOL) with an enhanced optic profile designed to mimic natural accommodation. PATIENTS AND METHODS Prospective multicenter clinical study with the new dual-optic aspheric accommodating IOL (Synchrony Vu) in 74 patients (148 eyes) undergoing cataract surgery. Refractive target was emmetropia. Examinations at 1 mo...
The main goal of a presbyopic patient is to reduce dependence on optical aids and improve both distance and near vision as well as the range of clear vision. Several studies report good safety, predictability, and efficacy outcomes in the implantation with monofocal, toric and multifocal intraocular lenses (IOLs) after refractive lens exchange (RLE). Patients with hybrid spherical IOLs show goo...
We report on a 72 year-old pseudophakic patient who had been implanted with a monofocal intraocular lens, and who underwent a unilateral Supracor laser-assisted in-situ keratomileusis (LASIK) procedure to correct presbyopia and hyperopia. Uncorrected near visual acuity was improved, but the patient complained of glare, halo, reduced distance vision, and poor night driving vision due to treatmen...
PURPOSE To determine whether the improvement in intermediate vision after bilateral implantation of an aspheric multifocal intraocular lens (IOL) with a +3.00 diopter (D) addition (add) occurs at the expense of optical quality compared with the previous model with a +4.00 D add. SETTING Department of Ophthalmology, University of São Paulo, São Paulo, Brazil. DESIGN Prospective randomized do...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید