نتایج جستجو برای: asymmetric wedged field output factor

تعداد نتایج: 1812658  

2017
Kananan Utitsarn Nauljun Stansook Michael L. F Lerch Marco Petasecca Anatoly B. Rosenfeld

We evaluate the impact of an air gap and optimization of this air gap for the MP512 silicon detector array when operated in dosimetry mode for small photon field measurements in solid water. We present output factor measurements for 6MV and 10 MV photon beams with the square field sizes ranging from 0.5 to 10 cm2. The size of the air gap above the MP512 detector was changed from 0.5, 1.0, 1.2, ...

Ahad Zeinali, Mikael mollazade samaneh ganjgahi

Introduction: Nowadays radiotherapy plays an important role in cancer treatment. Different radiotherapy techniques improvement emphasizes on using of the precise ، appropriate and useful algorithms. one of these techniques are wedged which is used in radiotherapy to compensate missing tissues and create a uniform dose distribution in tissues. The Siemens Artiste linear accelera...

2014
Tamer Dawod E. M. Abdelrazek Mostafa Elnaggar Rehab Omar

Aim: The purpose of this study was to make a comparison between measured and calculated physical wedge dose distributions using the superposition algorithm. Settings and Design: The accurate determination of absorbed dose is important radiotherapy because of the relatively steep sigmoidal dose response curves for both tumor control and normal-tissue damage. Materials and Methods: High-energy ph...

Journal: :Journal of Applied Clinical Medical Physics 2015

Introduction: In this study, dose distribution of the chest wall in post-mastectomy breast cancer patients was evaluated and compared in the tangential wedged beam (TWB) and field-in-field (FIF) plans. Materials and Methods: Thirty-six patients with left-sided breast cancer were enrolled in this study. The FIF and TWB plans were generated for each patient to compare dosimetric parameters of th...

2000
George Starkschall Roy E. Steadham Richard A. Popple Salahuddin Ahmad Isaac I. Rosen

Commissioning beam data for the convolution/superposition dose-calculation algorithm used in a commercial three-dimensional radiation treatment planning (3D RTP) system (PINNACLE(3), ADAC Laboratories, Milpitas, CA) can be difficult and time consuming. Sixteen adjustable parameters, as well as spectral weights representing a discrete energy spectrum, must be fit to sets of central-axis depth do...

A.R. Khoshbin Khoshnazar, M.T. Bahreyni Toossi,

Background: Radiosurgery is a focal brain irradiation technique that delivers, usually in a single session, high dose of ionizing radiation. The presence of lateral electronic disequilibrium and steep dose gradients in small fields demands special attention to the selection of a suitable detector with respect to its size, composition and response. Materials and Methods : Small circular fields w...

Journal: :Acta crystallographica. Section D, Biological crystallography 2006
José C Clemente Lakshmanan Govindasamy Amrita Madabushi S Zoë Fisher Rebecca E Moose Charles A Yowell Koushi Hidaka Tooru Kimura Yoshio Hayashi Yoshiaki Kiso Mavis Agbandje-McKenna John B Dame Ben M Dunn Robert McKenna

The malarial parasite continues to be one of the leading causes of death in many developing countries. With the development of resistance to the currently available treatments, the discovery of new therapeutics is imperative. Currently, the plasmepsin enzymes found in the food vacuole of the parasite are a chief target for drug development. Allophenylnorstatine-based compounds originally design...