Abstract The tip clearance size has historically been considered to be the main factor affecting stability range in axial fan and compressors. This paper reveals that stall characteristics are defined by momentum flux of leakage flow is primarily a strong driver for this metric. A bespoke methodology carefully tailoring via three-dimensional design presented, which enables higher degree control...