Journal: :Computer and Information Science 2011
Xuemei Bai Bin Guo Zhiyong An

As for the optical measurement, the longer the focal length of collimator is, the less the measurement error is. However, the longer the focal length is, the more difficult the optical design is. It's higher application value to design long focal length collimator with wide-view. The paper designs a collimator with 2000mm focal length, 4 degree field of view and its wavelength range is from 480...

2008
S. H. Ha M. J. Hamamura W. W. Roeck O. Nalcioglu D. J. Wagenaar D. Meier B. E. Patt

Purpose: Most of the nuclear imaging systems, especially those that are based on single photon emission detection, require the use of a collimatorusually made out of lead (Pb) or some other high Z material such as tungsten (W). Even some PET systems employ some sort of slat-septa collimation, although the important part of PET image formation is done electronically via coincidence detection. Mu...

Journal: :Clinical nuclear medicine 2013
Hiroto Yoneyama

PURPOSE The use of the low-energy high-resolution (LEHR) collimator for lymphoscintigraphy causes the appearance of star-shaped artifacts at injection sites. The aim of this study was to confirm whether the lower resolution of the low- to medium-energy general-purpose (LMEGP) collimator is compensated by decrease in the degree of septal penetration and the reduction in star-shaped artifacts. ...

Journal: :Physics in medicine and biology 1999
J Y Cheung K N Yu R T Ho C P Yu

The Leksell Gamma Knife is a standard radiosurgical tool for treating brain lesions by directing beams of gamma radiation to a specific region. The diameter of the gamma beams is confined by collimator systems and available collimator sizes are 4, 8, 14 and 18 mm. The reduction in dose rate for each collimator helmet is called the output factor (OPF). Experimental determination of OPFs is diffi...

2016
Amir M. Owrangi Donald A. Roberts Elizabeth L. Covington James A. Hayman Kathryn M. Masi Choonik Lee Jean M. Moran Joann I. Prisciandaro

To create a comprehensive dataset of peripheral dose (PD) measurements from a new generation of linear accelerators with and without the presence of a newly designed fetal shield, PD measurements were performed to evaluate the effects of depth, field size, distance from the field edge, collimator angle, and beam modi-fiers for common treatment protocols and modalities. A custom fetal lead shiel...

2015
Iori Sumida Hajime Yamaguchi Hisao Kizaki Keiko Aboshi Mari Tsujii Yuji Yamada Masashi Yagi Kazuhiko Ogawa

Pretreatment dose verification with beam-by-beam analysis for intensity-modulated radiation therapy (IMRT) is commonly performed with a gantry angle of 0° using a 2D diode detector array. Any changes in multileaf collimator (MLC) position between the actual treatment gantry angle and 0° may result in deviations from the planned dose. We evaluated the effects of MLC positioning errors between th...

2014
Song Gao Weiliang Du Peter Balter Peter Munro Andrew Jeung

The purpose of this study is to evaluate the accuracy and reproducibility of the IsoCal geometric calibration system for kilovoltage (kV) and megavoltage (MV) imagers on Varian C-series linear accelerators (linacs). IsoCal calibration starts by imaging a phantom and collimator plate using MV images with different collimator angles, as well as MV and kV images at different gantry angles. The sof...

Journal: :The Review of scientific instruments 2016
E E Scime A M Keesee M Dugas S Ellison J Tersteeg G Wagner A Barrie A Rager D Elliott

A plasma spectrometer design based on advances in lithography and microchip stacking technologies is described. A series of curved plate energy analyzers, with an integrated collimator, is etched into a silicon wafer. Tests of spectrometer elements, the energy analyzer and collimator, were performed with a 5 keV electron beam. The measured collimator transmission and energy selectivity were in ...