نتایج جستجو برای: concrete shear wall
تعداد نتایج: 306985 فیلتر نتایج به سال:
The structural integrity of precast concrete buildings depends mainly on the connections between the precast structural components. Large precast concrete panels are used extensively in North America for low, medium, and highrise construction due to their ease and speed of assembly, and high quality control. This paper presents the results of twenty-two prototype specimens tested to investigate...
A full-scale experimental program was used in this study to investigate the structural behavior of novel insulated concrete sandwich wall panels (SWPs) reinforced with grid-type glass-fiber-reinforced polymer (GFRP) shear connectors. Two kinds of insulation-expanded polystyrene (EPS) and extruded polystyrene (XPS) with 100 mm thickness were incased between the two concrete wythes to meet the in...
After learning from several devastating earthquakes in China in recent years, stricter design criteria have been introduced in the current Chinese seismic design code. To investigate the reliability of the current seismic design code, seismic fragility analyses were performed for 45 10-story reinforced concrete (RC) frame-shear wall structures designed according to the current Chinese seismic d...
Background and objective: Estimating the vulnerability rate of urban textures in seismic incident following a major earthquake (aftershocks) is crucial in decision making and crisis management. For this purpose, it is necessary to calculate the vulnerability of buildings due to the successive incidents and to use them in the vulnerability estimation for probable future aftershocks. Seismic frag...
دیوار برشی فولادی به عنوان یک سیستم باربر جانبی از سال 1970 میلادی در تعدادی از ساختمان های بلند جدید به خصوص در کشورهای ژاپن و آمریکا به کار رفته است. مطالعات انجام شده در مورد رفتار لرزه ای دیوارهای برشی فولادی و تجربیات گذشته نویدبخش یک سیستم بسیار موثر و شکل پذیر در برابر بارهای لرزه ای می باشد. مزایای استفاده از این سیستم شکل پذیری و قابلیت اتلاف انرژی نسبتاً بالا، سبکی نسبت به دیوار برشی ب...
The steel frame reinforced with steel shear wall is a lateral load resisting system and has higher strength and shear performance than the concrete shear wall system. Especially, using corrugated steel plates in these shear wall systems improves out-of-plane stiffness and flexibility in the deformation along the corrugation. In this paper, a cyclic loading test of this steel frame reinforced wi...
Precast load-bearing shear wall panels are used extensively for high-rise construction because of the ease and speed of assembly, and the high quality of the precast panels. The connections between panels are extremely important since they affect both the speed of erection and the overall integrity of the structure. This paper presents the results of a research program conducted to investigate ...
A full scale slice of a 7 story reinforced concrete building was tested on the shake table at the UCSD Engelkirk Structural Research Centre in 2006. As part of the research project, a blind prediction contest was sponsored to assess the capability of currently available analysis procedures to predict the seismic response of cantilever reinforced concrete shear wall structures. This paper descri...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید