نتایج جستجو برای: cylinder applicators

تعداد نتایج: 22009  

Journal: :Environmental research 1997
M M Amr Z S Halim S S Moussa

Two hundred eight pesticide formulators, 172 pesticide applicators, and 223 control subjects (72 from an urban region matching the pesticide formulators and 151 from a rural area matching the pesticide applicators) underwent psychiatric assessment. The study aimed to screen for psychiatric morbidity using a standardized screening tool, the General Health Questionnaire, and a widely recognized s...

2004
A. Kumar

A major characteristic in the hyperthermia technology is the ability to focus heat energy on a small region around the tumour to be treated. By applying Kirchhoff-Huygens principle and the scalar theory of diffraction, specific absorption rate (SAR) distribution in a homogeneous muscle due to arrays of open-ended rectangular waveguide as directcontact applicators (ORWDAs) at 915 MHz are calcula...

Hamid Reza Baghani, Nematollah Heidarloo, Seyed Mahmoud Reza Aghamiri

Introduction: Intraoperative electron radiation therapy (IOERT) is one of the cancer treatment techniques that delivers high doses to tumor bed during surgery. IOERT can be performed by either conventional LINACs or dedicated IORT accelerators such as LIAC (Light Intraoperative Accelerator). Two types of applicators can be used with LIAC dedicated accelerator including conventi...

2016
Grzegorz Zwierzchowski Grzegorz Bielęda Janusz Skowronek Magdalena Mazur

PURPOSE Well-known defect of TG-43 based algorithms used in brachytherapy is a lack of information about interaction cross-sections, which are determined not only by electron density but also by atomic number. TG-186 recommendations with using of MBDCA (model-based dose calculation algorithm), accurate tissues segmentation, and the structure's elemental composition continue to create difficulti...

2014
Hiroyuki Okamoto Ako Aikawa Akihisa Wakita Kotaro Yoshio Naoya Murakami Satoshi Nakamura Minoru Hamada Yoshihisa Abe Jun Itami

The influence of deviations in dwell times and source positions for (192)Ir HDR-RALS was investigated. The potential dose errors for various kinds of brachytherapy procedures were evaluated. The deviations of dwell time ΔT of a (192)Ir HDR source for the various dwell times were measured with a well-type ionization chamber. The deviations of source position ΔP were measured with two methods. On...

Journal: :American journal of epidemiology 2005
Laura E Beane Freeman Matthew R Bonner Aaron Blair Jane A Hoppin Dale P Sandler Jay H Lubin Mustafa Dosemeci Charles F Lynch Charles Knott Michael C R Alavanja

Little is known about the potential carcinogenicity associated with routine application of diazinon, a common organophosphate insecticide. The authors explored a possible association of diazinon exposure with cancer risk in the Agricultural Health Study, a prospective cohort of licensed pesticide applicators in Iowa and North Carolina enrolled in 1993-1997. A total of 23,106 male applicators pr...

2008
Torsten Anders Eduardo Reck Miranda

This paper studies how constraints are applied to the score in a musical constraint satisfaction problem (CSP). How can we control which variable sets in the score are affected by a given constraint? Our overall objective is to produce a highly generic music constraint system, where users can define a wide range of musical CSPs, including rhythmic, harmonic, melodic and contrapuntal problems. E...

Journal: :مجله علوم کشاورزی ایران 0
مجید لشگری حسین مبلی محمود امید رضا علیمردانی سید سعید محتسبی

the effective factors of forward speed, cylinder rotation, and clearance between a combine’s cylinder and concave on wheat kernel breakage and seed germination were studied in karaj area using a 955 model john dear combine. this study was conducted on three levels of adjustment for each of the variables, 1.2, 1.8 and 2.5 km/hr for forward speed, 800, 900, 1000 rpm for cylinder rotation as well ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید