نتایج جستجو برای: diamond dosimeter
تعداد نتایج: 23066 فیلتر نتایج به سال:
The purpose of this study was to evaluate dependence of PAGAT polymer gel dosimeter 1/T2 on different electron and photon energies for a standard clinically used Co therapy unit and an electa linear accelerator.Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2(1/T2) was determined to be 4.5% N,N'-methylen-bis-acrylamide(bis), 4.5% acrylamid(AA), 5% gelat...
In the European Community Respiratory Health Study (ECRHS), airway responsiveness to methacholine was determined using the Mefar dosimeter protocol. Elsewhere, the 2-min tidal breathing method has become the preferred standardized method. The relationship between measurements of responsiveness by these two methods is not well established. This study measured airway responsiveness to methacholin...
Polysulphone has been widely used as a dosimeter to quantify personal solar UV exposures to humans during normal daily activities. In summer at sub-tropical and tropical latitudes, the dynamic range for UV exposures allows the use of the polysulphone to measure solar UV over periods of approximately three to six hours. The use of mesh as a filter over the polysulphone has been previously report...
Monte Carlo water-equivalence study of two PRESAGE® formulations for proton beam dosimetry T Gorjiara, Z Kuncic, J Adamovics and C Baldock 2013 J. Phys.: Conf. Ser. 444 012090 PRESAGE® is a radiochromic solid dosimeter which shows promising potential for 3D proton beam dosimetry. Since an idea dosimeter should be water-equivalent, total depth dose distributions in two PRESAGE® formulations irra...
Spectrophotometric measurements of the Fricke–gelatin–xylenol orange (FGX) gel dosimeter demonstrated reproducible linear dose response up to 25Gy. However, oxidation processes continue post-irradiation, affecting the response of this dosimetry system. Additional oxygenation during preparation increases the sensitivity of the gel but does not improve the auto-oxidation stability of the dosimete...
Rhombellanes are mathematical structures existing in various environments, in crystal or quasicrystal networks, or even in their homeomorphs, further possible becoming real molecules. Rhombellanes originate in the K2.3 complete bipartite graph, a tile found in the linear polymeric staffanes. In close analogy, a rod-like polymer derived from hexahydroxy-cyclohexane was imagined. Further, the ide...
Radiographic or silver halide film is a well-established 2D dosimeter with an unquestioned spatial resolution. But its higher sensitivity to low-energy photons has to be taken into consideration. Metal compensators or physical modulators to deliver intensity modulated radiation therapy (IMRT) are known to change the beam energy spectrum and to produce scattered photons and contaminating electro...
OBJECTIVES To characterize exposures to noise and carbon monoxide (CO) among firefighters in British Columbia, Canada. METHODS Subjects were recruited from 13 fire halls across three municipalities in Metro Vancouver. Personal full-shift noise and CO samples were collected using datalogging noise dosimeters and CO monitors on both day and night shifts. Determinants of exposure (DoE) informati...
In recent years, interest in personal noise exposure has expanded beyond a workplace safety measure to become an effective means of investigating physiological effects of the acoustic environment on an individual. This work investigates the effects of the wearer's voice as a possible dominant sound source on body-mounted noise dosimeters and develops methods to improve the application of dosime...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید