نتایج جستجو برای: dispersive liquidliquid microextraction

تعداد نتایج: 20342  

2014
Laszlo Vincze

The latest developments in energy-dispersive X-ray detection technology combined with the use of sophisticated X-ray detector optics open new avenues for the determination of 2D/ 3D distribution of (trace) elements within the investigated samples on the microscopic scale. This work illustrates the development and applications of synchrotron radiation based micro-XRF/XAS imaging towards a fully ...

H. Bagheri Sadeghi M. Adibmehr Sh. Dehghan Abkenar

A simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (DLLME) was developed for determination and speciation of trace amounts of chromium (Cr) by flame atomic absorption spectrometry (FAAS). In the proposed approach, chloroform and methanol were used as extraction and dispersive solvents. A new Schiff's base ligand, bis(2-methoxy benzaldehyde) ethylene d...

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...

A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...

Journal: :Materials science & engineering. C, Materials for biological applications 2013
Kamal Alizadeh Hadi Nemati Somaieh Zohrevand Payman Hashemi Ali Kakanejadifard Mojtaba Shamsipur Mohammad Reza Ganjali Farnoush Faridbod

A simple, rapid and sensitive method was developed for the selective separation and preconcentration of Ni(II) using dispersive liquid-liquid microextraction, by a yellow Schiff's base bisazanyl derivative, as a selective complexing agent. In this method, a mixture of 45 μL chloroform (extraction solvent) and 450 μL tetrahydrofuran (dispersive solvent) is rapidly injected by syringe into a 5 mL...

Journal: :Journal of chromatographic science 2010
Huaixia Chen Hui Chen Lei Liao Jun Ying Jianlin Huang

Dispersive liquid-liquid microextraction (DLLME) coupled with high-performance liquid chromatography-variable wavelength detector (HPLC-VWD) was developed for extraction and determination of thiamphenicol (THA) in honey. A mixture of extraction solvent (30 microL 1,1,2,2-tetrachloroethane) and dispersive solvent (1.0 mL of acetonitrile) was rapidly injected into 5.00 mL sample solution for the ...

2010
Jing Cheng Yiwen Zhou Mei Zuo Liping Dai Xiaojie Guo

Dispersive liquid-liquid microextraction (DLLME) has been developed for the extraction and preconcentration of diethofencarb (DF) and pyrimethanil (PM) in environmental water. In the method, a suitable mixture of extraction solvent (50 μL carbon tetrachloride) and dispersive solvent (0.75 mL acetonitrile) are injected into the aqueous samples (5.00 mL) and the cloudy solution is observed. After...

Journal: :Microchemical Journal 2021

This work describes the development of an HPLC-FLD methodology for separation five fluoroquinolones (ciprofloxacin, enrofloxacin, sarafloxacin, norfloxacin and levofloxacin) followed by optimization DLLME process clean-up preconcentration enrofloxacin in samples seawater river water. The mobile phase used chromatographic consisted methanol: phosphate buffer (NaHPO4 H2O 0.04 M pH 3 with H3PO4 85...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید