Radiation therapy (RT) is a constantly evolving therapeutic technique; improvements are continuously being introduced for both methodological and practical aspects. Among the features that have undergone huge evolution in recent decades, dose calculation algorithms still rapidly changing. This process propelled by awareness agreement between delivered calculated doses of paramount relevance RT,...

Journal: :iranian journal of nuclear medicine 2003
kamal haddad mehrosadat alavi yeganeh gorji

determination of the total body absorbed dose consists of two parts: beta radiation absorbed dose and gamma radiation absorbed dose. the first part is generally determined by clinical data, while the second part has a parameter called absorbed ratio and is determined by computational methods. the monte-carlo computational methods have been shown to be the most suitable in determination of the a...

2002
Kent A. Gifford David S. Followill H. Helen Liu George Starkschall

An extensive set of measured data was developed for the purpose of verifying the accuracy of a photon dose-calculation algorithm. Dose distributions from a linear accelerator were measured using an ion chamber in a water phantom and thermoluminescent dosimeters in a heterogeneous anthropomorphic phantom. Test cases included square fields, rectangular fields, fields having different source-to-su...

2011
Veronica Ardu Sara Broggi Giovanni Mauro Cattaneo Paola Mangili Riccardo Calandrino

BACKGROUND To analyse limits and capabilities in dose calculation of collapsed-cone-convolution (CCC) algorithm implemented in helical tomotherapy (HT) treatment planning system for thorax lesions. METHODS The agreement between measured and calculated dose was verified both in homogeneous (Cheese Phantom) and in a custom-made inhomogeneous phantom. The inhomogeneous phantom was employed to mi...

2016
Indra Yohannes Heru Prasetio Karoline Kallis Christoph Bert

We report an investigation on the accuracy of dose calculation based on the cone-beam computed tomography (CBCT) images of the nonbowtie filter kV imaging system of the Vero linear accelerator. Different sets of materials and tube voltages were employed to generate the Hounsfield unit lookup tables (HLUTs) for both CBCT and fan-beam CT (FBCT) systems. The HLUTs were then implemented for the dos...

Journal: :iranian red crescent medical journal 0
sedigheh sina radiation research center, shiraz university, shiraz, ir iran reza faghihi radiation research center, shiraz university, shiraz, ir iran; department of nuclear engineering, shiraz university, shiraz, ir iran; radiation research center, shiraz university, shiraz, ir iran. tel: +98-7116473474, fax: +98-7116473474 ali soleimani meigooni department of nuclear engineering, shiraz university, shiraz, ir iran; comprehensive cancer center of nevada, las vegas, nevada, usa zahra siavashpour department of radiation medicine, shahid beheshti university, tehran, ir iran mohammad amin mosleh-shirazi center for research in medical physics and biomedical engineering, shiraz university of medical sciences, shiraz, ir iran; department of radiotherapy and oncology, shiraz university of medical sciences, shiraz, ir iran

conclusions according to the results, the old dosimetry formalisms, overestimate the dose especially towards the applicator’s tip. while the tg-43u1 based software perform the calculations more accurately. results for a typical arrangement of 10 active pellets in the applicator, the percentage difference between doses obtained by the new algorithm at 1cm distance from the tip of the applicator ...