نتایج جستجو برای: dose calculation accuracy

تعداد نتایج: 730852  

2016
Mareike Held Florian Cremers Penny K. Sneed Steve Braunstein Shannon E. Fogh Jean Nakamura Igor Barani Angelica Perez‐Andujar Jean Pouliot Olivier Morin

A clinical workflow was developed for urgent palliative radiotherapy treatments that integrates patient simulation, planning, quality assurance, and treatment in one 30-minute session. This has been successfully tested and implemented clinically on a linac with MV CBCT capabilities. To make this approach available to all clin-ics equipped with common imaging systems, dose calculation accuracy b...

Journal: :Nuclear technology 2009
Pablo Yepes Sharmalee Randeniya Phillip J Taddei Wayne D Newhauser

Monte Carlo codes are utilized for accurate dose calculations in proton radiation therapy research. While they are superior in accuracy to commonly used analytical dose calculations, they require significantly longer computation times. The aim of this work is to characterize a Monte Carlo track-repeating algorithm to increase computation speed without compromising dosimetric accuracy. The track...

Saju Bhasi, K. Abdul Haneefa, M.M. Musthafa, R. Ganapathi Raman, T. Siji Cyriac,

Background: The present work aims to study the out-of-field photon calculation accuracy of a commercial treatment planning system (TPS), Oncentra, for three-dimensional conformal radiotherapy (3D-CRT) and intensity modulated radiation therapy (IMRT) treatment techniques from Elekta Synergy medical linear accelerator. Materials and Methods: Accuracy of individual out-of-field dose components was...

2014
Kenichi Tanaka Kunihiko Tateoka Osamu Asanuma Ken-ichi Kamo Kaori Sato Hiromitsu Takeda Masaru Takagi Masato Hareyama Jun Takada

The post-implantation dosimetry for brachytherapy using Monte Carlo calculation by EGS5 code combined with the source strength regression was investigated with respect to its validity. In this method, the source strength for the EGS5 calculation was adjusted with the regression, so that the calculation would reproduce the dose monitored with the glass rod dosimeters (GRDs) on a water phantom. T...

2011
Aliaksandr Karotki Katherine Mah Gert Meijer Michael Meltsner

The use of magnetic resonance imaging (MRI) alone for radiation planning is limited by the lack of electron density for dose calculations. The purpose of this work is to evaluate the dosimetric accuracy of using bulk electron density as a substitute for computed tomography (CT)-derived electron density in intensity-modulated radiation therapy (IMRT) treatment planning of head and neck (HN) canc...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید