نتایج جستجو برای: dosimetric audit absolute photon dose linacs
تعداد نتایج: 491847 فیلتر نتایج به سال:
High-precision radiotherapy planning and quality assurance require accurate dosimetric and geometric phantom measurements. Phantom design requires materials with mechanical strength and resilience, and dosimetric properties close to those of water over diagnostic and therapeutic ranges. Plastic Water Diagnostic Therapy (PWDT: CIRS, Norfolk, VA) is a phantom material designed for water equivalen...
Background: Multiple beams are generally used with an increased possibility that the beam axis intersects the treatment table. Treatment tabletops are commonly made of carbon fiber due to its high mechanical strength and rigidity, low specific density, extremely light and low radiation beam attenuation properties. Purpose of this paper is investigated the dose changes in the buildup region and ...
BACKGROUND The purpose of this study was to perform a dosimetric comparison between proton beam therapy (PBT) and photon radiation therapy in patients with locally advanced esophageal squamous cell carcinoma (ESCC) who were treated with PBT in our institution. In addition, we evaluated the correlation between toxicities and dosimetric parameters, especially the doses to normal lung or heart tis...
Megavoltage electron beams represent an important treatment modality in modern radiotherapy, often providing a unique option in the treatment of superficial tumours (less than 5 cm deep). Electrons have been used in radiotherapy since the early 1950s, first produced by betatrons and then by microtrons and linacs. Modern high energy linacs typically provide, in addition to two megavoltage photon...
The clinical application of the flattening filter-free photon beam (FFF) has enjoyed greater use due to its advantage of reduced treatment time because of the increased dose rate. Its unique beam characteristics, along with the very high-dose rate, require a thorough knowledge of the capability and accuracy in FFF beam modeling, planning, and delivery. This work verifies the feasibility of mode...
background: the dosimetric performance of eclipse 6.5 three dimensional treatment planning system (3dtps) is evaluated by comparing the calculated and measured dose in two dimensions following the guide lines of american association for physicists in medicine task group 53. materials and methods: the calculations were performed by the 3dtps for symmetric as well as asymmetric fields for standar...
Purpose: To validate a locally fabricated phantom of Imatrixx-2D Array by comparing its results with ArcCheck phantom and comparing portal dosimetry measurements with the two phantom studies. Materials and Methods: Electronic Portal Imaging Devices and Epiqa software were used for portal dosimetry. An Imatrixx-2D array with a locally fabricated phantom and ArcCheck cylindrical phantom were used...
PURPOSE Thermoluminescent dosimeters are used routinely for dosimetric measurements of photon and electron fields. However, no work has been published characterizing TLDs for use in combined photon and electron fields. This work investigates the response of TLD-100 (LiF:Mg,Ti) in mixed fields of photon and electron beam qualities. METHODS TLDs were irradiated in a 6 MV photon beam, 6 MeV elec...
AIMS AND BACKGROUND A prospective analysis was carried out on a group of irradiated patients with pacemakers or implantable cardioverter-defibrillators to identify any relationship between the various types of devices and physical and dosimetric parameters. Cardiac toxicity of the treatment was also investigated. METHODS AND STUDY DESIGN Forty-five irradiated patients, implanted with pacemake...
~ The high temperature peaks (TL peaks 6-7) of TLD-600 are known to have higher responses to high LET radiation than to low LET radiation. These high temperature peak characteristics were studied for the automatic readerannealed Harshaw albedo neutron TLD. The high temperature peaks response is linear for neutrons over the dose equivalent range tested (0.05-3 mSv of a 252Cf source moderated by ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید