نتایج جستجو برای: doubly fed induction generator dfig

تعداد نتایج: 332492  

2016
Ping He Fushuan Wen Gerard Ledwich Yusheng Xue

The ever-increasing penetration of wind power integration into a power system can produce significant impacts on the operation of an interconnected power system. As the major energy conversion technology for large wind turbines, the doubly fed induction generator (DFIG) will play an important role in future power systems. Hence, the impacts of the DFIG on the low-frequency oscillations of inter...

2004
Ted Brekken Ned Mohan

Wind energy is often installed in rural, remote areas characterized by weak, unbalanced power transmission grids. In induction wind generators, unbalanced three phase stator voltages cause a number of problems, including overheating and stress on the mechanical components from torque pulsations. Therefore, beyond a certain amount of unbalance (for example 6%), induction wind generators are swit...

In this paper, a new sensorless model reference adaptive method is used for direct control of active and reactive power of the doubly fed induction generator (DFIG). In order to estimate the rotor speed, a high frequency signal injection scheme is implemented. In this study, to improve the accuracy of speed estimation, two methods are suggested. First, the coefficients of proportional-integral ...

2016
Bhinal Mehta Praghnesh Bhatt Vivek Pandya

This paper presents the state space modelling of doubly fed induction generator (DFIG) for small signal stability assessment. The gains of PI controller in torque and voltage control loop of rotor-side converter (RSC) are optimized by particle swarm optimization (PSO) to improve the dynamic performance of DFIG. These optimized parameters results in improved damping of DFIG and minimizes the osc...

2018
K. Gopinath C. Baskaran

The Doubly Fed Induction Generator (DFIG) is getting wider popularity due to its ability to adapt with variable wind speed and to capture more wind energy. Though DFIG has a salient feature of the fault ride through capability, this is not sufficient to preserve the necessity of the grid code when the DFIG system is connected with the grid. To accomplish this goal, a DC resistive superconductin...

2016
M.BHANU PRAKASH

This paper presents the operation of doubly fed induction generator (DFIG) with Fuzzy Logic Control & an integrated active filter capabilities using grid-side converter (GSC). The main contribution of this work lies in the control of GSC using Fuzzy Logic Control (FLC) for supplying harmonics in addition to its slip power transfer. The rotor-side converter (RSC) is used for attaining maximum po...

2015
A. Boualouch A. Essadki A. Boukhriss

Abstract—This paper presents a power control for a Doubly Fed Induction Generator (DFIG) using in Wind Energy Conversion System (WECS) connected to the grid. The proposed control strategy employs two nonlinear controllers, Backstipping (BSC) and slidingmode controller (SMC) scheme to directly calculate the required rotor control voltage so as to eliminate the instantaneous errors of active and ...

Journal: :EAI endorsed transactions on internet of things 2021

The quality of service and the respect contractual characteristics voltage is a major issue transmission system operator. In this context, code requires that wind turbine participate in regulation voltage. Any variation must be compensated by producing or absorbing reactive power. This article studies modelling control strategies energy conversion based on doubly fed induction generator. It pre...

2016
Mallala Harshavardhan

Now a days wind power energy is playing a major role in power industry. With the raise in application of the wind power variety of topologies are emerging into picture. Within the various types of adjustable speed fixed frequency topologies DFIG is most preferred type because of its efficiency as well as capability to allow wide range of speed variance at simplified converter size. Doubly Fed I...

2013
Bhola Jha

Doubly Fed Induction Generator (DFIG) finds wide applications in wind energy that keeps on changing. Also, Small disturbances refer to transients; can be modeled as the change in load to DFIG system occurs more frequently. Therefore understanding the transient operation of DFIG became very much interesting and challenging. This is desired that the system should able to digest such disturbances....