2003
J. I. Prisciandaro M. G. Herman J. J. Kruse

A method to investigate light and radiation field congruence utilizing a commercially available amorphous silicon electronic portal imaging device (EPID) was developed. This method employed an EPID, the associated EPI software, and a diamond-shaped template. The template was constructed from a block tray in which Sn/Pb wires, 1 mm in diameter, were embedded into a diamond shaped groove milled i...

Journal: :Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 1995
M L Dirkx M Kroonwijk J C de Boer B J Heijmen

The MM50 Racetrack Microtron, suited for advanced three-dimensional conformal radiotherapy techniques, is a complex machine in various respects. Therefore, for a number of gantry angles, daily quality control of the absolute output and fluence profiles of the scanned beams are mandatory. For the applied photon beams, a fast method for these daily checks, based on dosimetric measurements with th...

Journal: :Medical physics 2002
Sandra C Vieira Maarten L P Dirkx Kasper L Pasma Ben J M Heijmen

A prerequisite for accurate dose delivery of IMRT profiles produced with dynamic multileaf collimation (DMLC) is highly accurate leaf positioning. In our institution, leaf verification for DMLC was initially done with film and ionization chamber. To overcome the limitations of these methods, a fast, accurate and two-dimensional method for daily leaf verification, using our CCD-camera based elec...

2015
Jinhan Zhu Lixin Chen Along Chen Guangwen Luo Xiaowu Deng Xiaowei Liu

PURPOSE To use a graphic processing unit (GPU) calculation engine to implement a fast 3D pre-treatment dosimetric verification procedure based on an electronic portal imaging device (EPID). METHODS The GPU algorithm includes the deconvolution and convolution method for the fluence-map calculations, the collapsed-cone convolution/superposition (CCCS) algorithm for the 3D dose calculations and ...

2017
Arpita Agarwal Nikhil Rastogi K. J. Maria Das S. A. Yoganathan D. Udayakumar Shaleen Kumar

PURPOSE With the advent of state-of-the-art treatment technologies, the use of small fields has increased, and dosimetry in small fields is highly challenging. In this study, the potential use of Varian electronic portal imaging device (EPID) for small field measurements was explored for 6 and 15 MV photon beams. MATERIALS AND METHODS The output factors and profiles were measured for a range ...

Journal: :Medical physics 2004
L N McDermott R J W Louwe J J Sonke M B van Herk B J Mijnheer

The purpose of this study was to investigate the dose-response characteristics, including ghosting effects, of an amorphous silicon-based electronic portal imaging device (a-Si EPID) under clinical conditions. EPID measurements were performed using one prototype and two commercial a-Si detectors on two linear accelerators: one with 4 and 6 MV and the other with 8 and 18 MV x-ray beams. First, t...

Journal: :Medical physics 2006
Laure Parent Joao Seco Phil M Evans Andrew Fielding David R Dance

This study focused on predicting the electronic portal imaging device (EPID) image of intensity modulated radiation treatment (IMRT) fields in the absence of attenuation material in the beam with Monte Carlo methods. As IMRT treatments consist of a series of segments of various sizes that are not always delivered on the central axis, large spectral variations may be observed between the segment...