نتایج جستجو برای: electrospray ionization esi

تعداد نتایج: 47193  

Journal: :The Analyst 2010
Catherine H Stephens Bindesh Shrestha Hannah R Morris Mark E Bier Paul M Whitmore Akos Vertes

Minimally invasive desorption electrospray ionization-mass spectrometry (DESI-MS) and laser ablation electrospray ionization-MS (LAESI-MS) were used to look for soluble cellulose degradation products produced by accelerated aging in unsized cotton paper. Soluble extracts from papers aged 144 to 26,856 hours were first analyzed in solution using traditional electrospray ionization-MS (ESI-MS). R...

2011
Heather D. Bean Jiangjiang Zhu Jane E. Hill

Secondary electrospray ionization mass spectrometry (SESI-MS) is a method developed for the rapid detection of volatile compounds, without the need for sample pretreatment. The method was first described by Fenn and colleagues and has been applied to the detection of illicit drugs and explosives, the characterization of skin volatiles, and the analysis of breath. SESI ionization occurs by proto...

Journal: :Dalton transactions 2015
Qiaodi Jia Jie Cao Yunpeng Duan Changwen Hu

The solution chemistry of a series of mono-, di- and trilacunary Keggin silicotungstates was investigated by electrospray ionization mass spectrometry (ESI-MS) and general electrospray features especially for lacunary POMs are summarized. The reactions of vanadium incorporation into the lacunary structures were successfully monitored in real-time by a combination of ESI-MS and differential puls...

Journal: :Journal of chromatography. B, Analytical technologies in the biomedical and life sciences 2004
Werawan Ruangyuttikarn Ivan Miksik Jeeraporn Pekkoh Yuwadee Peerapornpisal Zdenek Deyl

Reversed-phase HPLC coupled to the atmospheric pressure ionization-electrospray ionization (API-ESI) MS was used for microcystin-LR detection and quantitation in samples of dried Microcystis aeruginosa cells. An alkaline linear gradient (20 mmol/l ammonium hydroxide-acetonitrile, pH 9.7) was used for elution of the toxic peptides. Limit of detection was 1 microg/ml (20 ng per injection) in the ...

2007
Fanny Guzmán Sonia Barberis Andrés Illanes

Abbreviations: CD: circular dichroism CLEC: cross linked enzyme crystals DDC: double dimer constructs ESI: electrospray ionization HOBT: hydroxybenzotriazole HPLC: high performance liquid hromatography KCS: kinetically controlled synthesis MALDI: matrix-assisted laser desorption ionization MAP: multiple antigen peptide system MS: mass spectrometry NMR: nuclear magnetic resonance SPS: solution p...

2015
Karina Tveen-Jensen Frank Gesellchen Rab Wilson Corinne M. Spickett Jonathan M. Cooper Andrew R. Pitt

Soft ionization methods for the introduction of labile biomolecules into a mass spectrometer are of fundamental importance to biomolecular analysis. Previously, electrospray ionization (ESI) and matrix assisted laser desorption-ionization (MALDI) have been the main ionization methods used. Surface acoustic wave nebulization (SAWN) is a new technique that has been demonstrated to deposit less en...

2014
Rob Haselberg Chitra K. Ratnayake Gerhardus J. de Jong Govert W. Somsen

There is a growing need for selective and sensitive analytical tools for the characterization of intact proteins. The effective coupling of capillary electrophoresis and electrospray ionization timeof-fl ight mass spectrometry (CE-ESI-TOF-MS) may offer an attractive option by providing both the separation and detection required to distinguish structurally-related protein species [1,2]. In order...

Journal: :Journal of mass spectrometry : JMS 2005
Arno Wortmann Francesco Rossi Gerald Lelais Renato Zenobi

We present an improvement of the titration method for binding constant determination with electrospray ionization (ESI) mass spectrometry that is unaffected by differences in ESI response of measured species in solution. The method consists of a calibration and titration, both using an internal standard that allows relative quantitation. This avoids artifacts such as a decrease in overall signa...

Journal: :Analytical chemistry 2008
Jason S Page Keqi Tang Ryan T Kelly Richard D Smith

A nanoelectrospray ionization mass spectrometry (ESI-MS) source and interface has been designed that enables efficient ion production and transmission in a 30 Torr pressure environment using solvents compatible with typical reversed-phase liquid chromatography (RPLC) separations. In this design, the electrospray emitter is located inside the mass spectrometer in the same region as an electrodyn...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2008
Hiroki Hotta Qiang Wang Mioko Fukuda Shoichi Aizawa Tomonari Umemura Kazutoshi Sekizawa Kin-ichi Tsunoda

The use of electrospray ionization mass spectrometry (ESI-MS) in negative ion mode was investigated as a direct probe for identifying Al species in Al-accumulating hydrangea (Hydrangea macrophylla) samples. Cell sap solutions of hydrangea leaves were purified using Sephadex G-10 liquid chromatography and each fraction was analyzed using ESI-MS and ESI-MS/MS to identify Al species. In hydrangea ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید