H. Zare, M. Nazery, M.T. Bahreyni Toosi,

Background: Application of Dose-area product (DAP) quantity has been increased in the clinical practice. DAP is relatively easy to measure. DAP has been shown to correlate well with the total energy imparted to the patient, which is related to the effective dose. Material and Methods: In this study, measurements of DAP were carried out in a sample of 421 adult patients who underwent convention...

Journal: :Radiation protection dosimetry 2008
R Padovani E Vano A Trianni C Bokou H Bosmans D Bor J Jankowski P Torbica K Kepler A Dowling C Milu V Tsapaki D Salat J Vassileva K Faulkner

In interventional cardiology, a wide variation in patient dose for the same type of procedure has been recognised by different studies. Variation is almost due to procedure complexity, equipment performance, procedure protocol and operator skill. The SENTINEL consortium has performed a survey in nine european centres collecting information on near 2000 procedures, and a new set of reference lev...

2016
Tohru Okazaki Hiroaki Hayashi Kazuki Takegami Hiroki Okino Natsumi Kimoto Itsumi Maehata Ikuo Kobayashi

Background: In order to manage the patient exposure dose in X-ray diagnosis, it is preferred to evaluate the entrance skin dose; although there are some evaluations about entrance skin dose, a small number of report has been published for direct measurement of patient. We think that a small-type optically stimulated luminescence (OSL) dosimeter, named nanoDot, can achieve a direct measurement. ...

2000
Robert R. Wilson

9.1 Background to Proton Therapy The use of proton beams for radiation treatment was proposed by Robert R. Wilson in 1946 [286]. Wilson referred to the ballistical aspects of the proton beam dose distribution as a rationale for the new modality. Heavy charged particles such as protons produce an energy deposition profile in tissue which is superior to profiles attainable using photon or electro...

Journal: :AJNR. American journal of neuroradiology 1994
P Bergeron R Carrier D Roy N Blais J Raymond

PURPOSE To evaluate stochastic and deterministic risks associated with neurointerventional procedures for the patient. METHODS Eight neurovascular interventional procedures were evaluated to determine the entrance skin dose and effective dose for the patient. Dosimetry was done with thermoluminescence dosimeters. The highest dose on the patient's head was recorded as the maximum entrance skin...

Journal: :Circulation 1994
A den Boer P J de Feyter W A Hummel D Keane J R Roelandt

BACKGROUND Radiographic technology plays an integral role in interventional cardiology. The number of interventions continues to increase, and the associated radiation exposure to patients and personnel is of major concern. This study was undertaken to determine whether a newly developed x-ray tube deploying grid-switched pulsed fluoroscopy and extra beam filtering can achieve a reduction in ra...

Introduction: Phantom studies facilitate the implementation of radiation dose surveillance as a function of radiographic technical parameters for minimizing patient radiation dose. The evidence of such investigations can then be used to evaluate technical parameters used in the radiographic procedures to reduce radiation dose without compromising the image quality. Material and Methods: This ex...

Introduction: Extensive use of diagnostic radiology is the largest contributor to total population radiation doses. Thus, appropriate equipment and safe practice are necessary for good-quality images with optimal doses. This study aimed to perform quality control (QC) audit for radiography and fluoroscopy devices owned by private sector in Syria (2005-2013) to verify compliance of performance o...

Journal: :international journal of marine science and engineering 2013
m. mojabi k. hejazi m. karimi

sedimentation is one of the most important problems in harbors that results in considerable economic costs. harbor planforms affects the flow pattern in the harbor basin and consequently, plays an important role in sediment transport and sedimentation. in the present study, a two dimensional depth-averaged hydrodynamic and sediment transport model has been developed to investigate the effect of...

Introduction: One of the useful standard quality assurance techniques in radiation therapy is monitoring entrance doses in in-vivo dosimetry. An overall tolerance limit of 5% of the absorbed radiation dose has been recommended by the International Commission of Radiological Units. The implementation of an in vivo dosimet...