Journal: :Medical physics 2014
R Lafratta J Yang N Sahoo S Tucker D Followill G Ibbott

PURPOSE To compare gamma calculations from 2D and 3D dosimetry measurements for phantom quality assurance. METHODS An IROC Houston (RPC) head and neck phantom was irradiated with a 9 beam IMRT plan using two inserts: a TLD and film insert and a PRESAGE insert. Both inserts were irradiated 3 times. The film and PRESAGE doses were scaled to the TLD dose and 2D gamma calculations were made in th...

Journal: :Physics in medicine and biology 2011
Andrew Kelly Nicholas Hardcastle Peter Metcalfe Dean Cutajar Alexandra Quinn Kerwyn Foo Michael Cardoso Sheree Barlin Anatoly Rosenfeld

Curative breast radiotherapy typically leaves patients with varying degrees of cosmetic damage. One problem interfering with cosmetically acceptable breast radiotherapy is the external contour for large pendulous breasts which often results in high doses to skin folds. Thermoplastic casts are often employed to secure the breasts to maintain setup reproducibility and limit the presence of skin f...

2014
R Lafratta G Ibbott J Adamovics D Followill

Gamma index pass rates were evaluated for an anthropomorphic phantom using both 2D and 3D calculations. The phantom was irradiated with the traditional dosimetry insert loaded with radiochromic film and TLD, and then with a 3D dosimetry insert. A comparison with the calculated dose distribution showed that both the PRESAGE ® dosimeter and the film and TLD system agreed with the plan to within 5...

2013
N. Malathi P. Sahoo K. Praveen N. Murali

The paper presents an innovative approach towards development of real time dosimetry using a chemical dosimeter for measurement of absorbed radiation dose in the range between 1 and 400 Gy. Saturated chloroform solution in water, a well known chemical dosimeter, is used to demonstrate the concept of online measurement of radiation dose. The measurement approach involves online monitoring of inc...

2016
Sandra Sarmento Joana Pereira Maria José Sousa Luís Cunha Anabela G. Dias Miguel F. Pereira Augusto D. Oliveira João V. Cardoso Luís M. Santos Margarida Gouvêa Joana Lencart João G. Alves João A.M. Santos

Computed tomography fluoroscopy (CTF) is a useful imaging technique to guide biopsies, particularly lung biopsies, but it also has the potential for very high hand exposures, despite use of quick-check method and needle holders whenever feasible. Therefore, reliable monitoring is crucial to ensure the safe use of CTF. This is a challenge, because ring dosimeters monitor exposure only at the bas...

Journal: :Physics in medicine and biology 2016
Luc Beaulieu Sam Beddar

While scintillation dosimetry has been around for decades, the need for a dosimeter tailored to the reality of modern radiation therapy-in particular a real-time, water-equivalent, energy-independent dosimeter with high spatial resolution-has generated renewed interest in scintillators over the last 10 years. With the advent of at least one commercial plastic scintillation dosimeter and the eve...

2000
MIHOKO HAREYAMA NORIYOSHI TSUCHIYA MASAHIRO TAKEBE TADASHI CHIDA

Two-dimensional measurement of radiation produced by natural irradiation of granitic rocks was performed by the use of an imaging plate, which is a storage film coated with photostimulated phosphor (BaFBr:Eu2+). Radiation images of small volume specimens, such as thin sections were obtained with the imaging plate. Irradiation images of granitic rocks are inhomogeneous and the intensity of photo...

2017
E. Tchistiakova A. Kim W. Y. Song G. Pang

Magnetic resonance imaging (MRI) is being rapidly integrated for cancer treatments-such systems are referred to as MRI-guided radiation therapy (MRIgRT). As the magnet of an MRI scanner is always on, the presence of a strong static magnetic field from the MRI scanner during radiotherapy delivery presents new challenges. One of the challenges is that a personal radiation dosimeter used to estima...

2017
E E Carpentier K M Alexander S Todd L J Schreiner

A radiochromic silicone based dosimeter has been fabricated that allows for threedimensional (3D) dose verification. This paper characterizes the silicone dosimeter and verifies previous results found by other research groups. Using a recipe found to be dose rate independent, we identify the spectra of the dosimeter irradiated to different doses and verify that the response from different dose ...

1998
Dave Smith Ian Searle

The Damage Dosimeter has been designed to fill a void in commercially available data recorders. The United States Air Force often has the need to measure structural strains and temperatures on in-service aircraft in order to diagnose difficult-to-analyze structural conditions, such as high cycle fatigue. To perform these functions a rugged, small, and lightweight data acquisition unit called th...