نتایج جستجو برای: fracture of tibial shaft

تعداد نتایج: 21177326  

2016
Wen-Wei Dong Zeng-Yuan Shi Zheng-Xin Liu Hai-Jiao Mao

PURPOSE To describe an indirect reduction technique during minimally invasive percutaneous plate osteosynthesis (MIPPO) of tibial shaft fractures with the use of a distraction support. METHODS Between March 2011 and October 2014, 52 patients with a mean age of 48 years (16-72 years) sustaining tibial shaft fractures were included. All the patients underwent MIPPO for the fractures using a dis...

Journal: :Orthopedics 2012
Julius A Bishop Gregory D Dikos Dayne Mickelson David P Barei

Some tibial shaft fractures cannot be accurately reduced using closed or percutaneous techniques during an intramedullary nailing procedure. Under these circumstances, a formal open reduction can be performed. Direct exposure of the fracture facilitates accurate reduction but does violate the soft tissue envelope. The purpose of this study was to evaluate the safety and efficacy of open reducti...

Journal: :Gait & posture 2017
Peter Larsen Uffe Laessoe Sten Rasmussen Thomas Graven-Nielsen Christian Berre Eriksen Rasmus Elsoe

INTRODUCTION Despite the high number of studies evaluating the outcomes following tibial shaft fractures, the literature lacks studies including objective assessment of patients' recovery regarding gait pattern. The purpose of the present study was to evaluate whether gait patterns at 6 and 12 months post-operatively following intramedullary nailing of a tibial shaft fracture are different comp...

2017
Tomohiro Yasuda Masayuki Arai Kaoru Sato Koji Kanzaki

INTRODUCTION In the treatment of Gustilo Type 3B open tibial fractures, it is important to perform soft tissue reconstruction and bone reconstruction simultaneously. Gastrocnemius muscle and soleus muscle flaps are generally used as rotational flaps for the tibia. The distal third of the tibia can often not be covered with the gastrocnemius muscle and soleus muscle flaps. Treatment distal to th...

2014
Metin Uzun Adnan Kara Müjdat Adaş Bülent Karslioğlu Murat Bülbül Burak Beksaç

Purpose. We evaluated whether intramedullary nail fixation for tibial diaphysis fractures with concomitant fibula fractures (except at the distal one-third level) managed conservatively with an associated fibula fracture resulted in ankle deformity and assessed the impact of the ankle deformity on lower extremity function. Methods. Sixty middle one-third tibial shaft fractures with associated f...

2016
Caio Zamboni Felipe Augusto Garcez de Campos Noel Oizerovici Foni Rafael Carboni Souza Ralph Walter Christian Marcelo Tomanik Mercadante

The authors report on a case of tibial shaft fracture associated with ankle injury. The clinical, radiological and surgical characteristics are discussed. Assessment of associated injuries is often overlooked and these injuries are hard to diagnose. When torque occurs in the lower limb, the ankle becomes susceptible to simultaneous injury. It is essential to make careful assessment based on cli...

2015
Ayyoub A Mohammed Mohanad H Hasan Rami Ahmed

Patients and Methods: From April 2009 to January 2014, we treated 91 patients with high-energy fractures of the tibial shaft at Orthopedic Department of AlRamadi Teaching Hospital. Twenty patients were suitable for our study that had closed segmental fractures of tibial shaft (42-C2 / AO classification), treated by minimal, internal and external, fixations with follow up range from 6 months to ...

Journal: :Journal of orthopaedic surgery 2007
S Gupta M A Fazal F Haddad

We report a case of traumatic anterior dislocation of the left knee with an ipsilateral tibial shaft fracture in association with popliteal artery and common peroneal nerve injuries. To our knowledge, such a combination of injuries has not been reported before. All components of this injury were recognised and treated promptly with rehabilitation commencing early, resulting in a good functional...

Journal: :Journal of children's orthopaedics 2011
Nirav K Pandya Eric W Edmonds Scott J Mubarak

PURPOSE Pediatric tibial shaft fractures are common injuries encountered by the orthopaedic surgeon. Flexible intramedullary nailing has become popular for pediatric patients with tibial shaft fractures that require operative fixation. The purpose of our study was to evaluate the incidence of, and the risk factors for, compartment syndrome (CS) after flexible intramedullary nailing of these inj...

2010
Colin Yi-Loong Woon Merng-Koon Wong Tet-Sen Howe

The locking compression plate (LCP) is an angle-stable fixator intended for intracorporeal application. In selected cases, it can be applied externally in an extracorporeal location to function as a monolateral external fixator. We describe one patient with Schatzker V tibial plateau fracture and one patient with Gustillo IIIB open tibia shaft fracture treated initially with traditional externa...

نمودار تعداد نتایج جستجو در هر سال