نتایج جستجو برای: gel dosimetry
تعداد نتایج: 112840 فیلتر نتایج به سال:
background: polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. mri polymer gel dosimeters are tissue equivalent and can act as a phantom material. in this study the obtained isodose maps with pagat polymer gel dosimeter were compared to those calculated with egsnrs for singleshot irradiations of 8 and 18 mm collimators of gamma ...
High-molecular gel containing capsulate thermo-chromic liquid crystal is made to visualize three-dimensional distribution of electromagnetic power absorption. A preliminary experiment is performed at frequency of 1.5GHz. As a result of the experiment, the three-dimensional distribution of electromagnetic power absorption is clearly visualized. The result shows that the gel can be used as a phan...
Boron neutron capture therapy (BNCT) is a form of chemically targeted radiotherapy that utilises the high neutron capture cross-section of boron-10 isotope to achieve a preferential dose increase in the tumour. The BNCT dosimetry poses a special challenge as the radiation dose absorbed by the irradiated tissues consists of several dose components with different relative biological effectiveness...
Gel dosimetry is a promising technique for the implementation of 3D dose verification within the radiation therapy clinic, since it is the only methodology which provides comprehensive 3D dose measurement of conformal treatments such as Intensity Modulated Radiation Therapy (IMRT), Stereotactic radiosurgery (SRS) and Stereotactic Radiotherapy (SRT), and volumetric arc therapies (VMAT). In polym...
Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...
Introduction: The objective of this work is to study the ability of MRI normoxic polymer gel dosimetry system to be used to verify the calculated dose distribution, in a simple geometry, in clinical radiotherapy. Materials and Methods: Initially, 2 liters of the normoxic MAGAT polymer gel was prepared and then poured into two cylindrical Perspex phantom (simu...
Tetrazolium salts (TS) have been previously used for radiochromic dosimetry in solutions, films and three dimensional (3D) gelatine-based gels. However, widespread application for 3D dosimetry has not been achieved due to the required high concentrations and associated high costs of the TS dimer used in prior research. Through careful selection of TS monomer, sensitivity-enhancing additives and...
Much of the complex medical physics work requires radiation dose delivery, which dosimeters to accurately measure three-dimensional distribution with good spatial resolution. MAGIC-f polymer gel is one emerging new widely used in research. The purpose this study was present an overview dosimetry, using gel, including its composition, manufacture, imaging, calibration, and application In review,...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید