نتایج جستجو برای: high frequency transformer design

تعداد نتایج: 3145461  

2014
S. Kanimozhi V. Rajini

This paper presents implementations of a nonisolated, high voltage gain DC-DC converter. High voltage gain is achieved due to inclusion of resonance and transformer in the circuit. The performance of this converter is compared with two similar topologies namely coupled inductor-switched capacitor step-up converter and coupled inductor step-up converter. The proposed prototype is designed using ...

Journal: :IEEE Trans. Industrial Electronics 2002
Xiaoming Yuan Ivo Barbi

This paper proposes a transformer-assisted pulsewidth-modulation zero-voltage-switching neutral-pointclamped (NPC) inverter. With the assistance of a transformer-assisted small-rating lossless auxiliary circuit, the main switches work with zero-voltage switching without suffering from any voltage/current spikes, under simple explicit control. The technique allows for higher operating frequency ...

2008
Xiao-Yuan Chen Jian-Xun Jin

⎯With the improvement of high temperature superconductor (HTS) practical performance, research and development concerning the applications of HTS transformers have been progressed actively worldwide. This paper provides a comprehensive summary on various HTS transformers, and studies the design of a single-phase 10 kVA (220V/24V) HTS transformer prototype to verify HTS for practical transformer...

Journal: :The Review of scientific instruments 2011
Akira Homma

A novel annular parallel-strip transmission line was devised to construct high-voltage high-speed pulse isolation transformers. The transmission lines can easily realize stable high-voltage operation and good impedance matching between primary and secondary circuits. The time constant for the step response of the transformer was calculated by introducing a simple low-frequency equivalent circui...

Journal: :IEICE Transactions 2010
Eunil Cho Sungho Lee Jaejun Lee Sangwook Nam

This paper presents a design of a monolithic transformer using bond wires. The proposed transformer structure has several advantages such as high power handling and high efficiency. It shows that the measured insertion loss at the 1.9 GHz range is −1.54 dB (70%), which is higher than the spiral transformer of the same size. Also, it shows a phase error of less than 1 degree. key words: CMOS RF ...

2016
Chao Geng Fenghua Wang Jun Zhang Zhijian Jin

Modal parameters of power transformer winding are closely related to transformer manufacturing and detection technology of winding deformation based on vibration analysis method. Aimed at identifying the modal parameters of transformer winding accurately, a modal experiment is designed and made on a real 10 kV power transformer. An improved Empirical Mode Decomposition (EMD) algorithm is propos...

2012
R. Sarathi G. Koperundevi

Design of Converter transformer insulation is a major challenge. The insulation of these transformers is stressed by both AC and DC voltages. Particle contamination is one of the major problems in insulation structures, as they generate partial discharges leading it to major failure of insulation. Similarly corona discharges occur in transformer insulation. This partial discharge due to particl...

2007
MOHAMMAD S. NADERI M. VAKILIAN T. R. BLACKBURN T. B. PHUNG MEHDI S. NADERI

Partial discharges (PD) are recognized as the main cause of the inner insulation deterioration process in power transformers. Therefore, the optimum inner insulation design is one of the challenges a transformer designer is faced with. Transformer strength, especially during transient conditions, is a criterion for transformer insulation designers. This challenge has made designers initiate and...

2007
Duo Chen Haiyu Yu Jiansheng Yuan

The MV/LV transformer without a tank in the underground substation can produce remarkable interference with the computer Cathode-Ray Tube (CRT) displayers above the ground, because of the generated power frequency magnetic field. To resolve such problem, a tank with high conductivity or/and high permeability is needed to enclose the transformer. To evaluate the shielding effectiveness, the fini...

Journal: :Magnetism 2022

The design of medium- to high-frequency power electronics transformer aims not only minimize the loss in windings and core, but its heat removal features should also allow optimal use both core copper. feature (e.g., thermal conduction) a is complex because there exist multiple centers. bulk total concentrated around small segment assembly where are overlaid. primary winding most constrained th...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید