نتایج جستجو برای: implant geometry

تعداد نتایج: 190677  

Journal: :journal of dentistry, tehran university of medical sciences 0
farhad tabatabaian assistant professor, department of prosthodontics, dental school, shahid beheshti university of medical sciences, tehran, iran. abolfazl saboury associate professor, department of prosthodontics, dental school, shahid beheshti university of medical sciences, tehran, iran. zahra sadat sobhani former student, dental school of shahid beheshti university of medical sciences, tehran, iran. vicki c petropoulos associate professor, department of preventive and restorative sciences, university of pennsylvania school of dental medicine, united states.

the effect of inter-implant distance on retention and resistance of implant-tissue-supported overdentures is lacking in the literature. an in vitro study was performed to evaluate this effect for mandibular implant-tissue-supported overdentures retained by two ball attachments.an acrylic cast of an edentulous mandible was fabricated. three pairs of implants were symmetrically placed at both sid...

Journal: :avicenna journal of dental research 0
masoumeh khoshhal department of periodontics, school of dentistry, hamadan university of medical sciences, hamadan, ir iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی همدان (hamadan university of medical sciences) fariborz vafaei department of prosthodontics, school of dentistry, hamadan university of medical sciences, hamadan, ir iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی همدان (hamadan university of medical sciences) banafsheh poormoradi department of periodontics, school of dentistry, hamadan university of medical sciences, hamadan, ir iran; department of periodontics, school of dentistry, hamadan university of medical sciences, hamadan, ir iran. tel: +98-9188124251, fax: +98-8138381085سازمان اصلی تایید شده: دانشگاه علوم پزشکی همدان (hamadan university of medical sciences) janet moradi haghgoo department of periodontics, school of dentistry, hamadan university of medical sciences, hamadan, ir iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی همدان (hamadan university of medical sciences) faezeh behgozin dentist, hamadan, ir iran neda amiri dentist, hamadan, ir iran

results the mean distances between the crestal bone and the implant shoulder in group 1 were 1.01, 1.44, and 1.93 mm at the implant placement time, and at the 6 and 12-month postoperative intervals, respectively. in group 2, these distances were 1.35, 1.20, and 1.41 mm, respectively. there were no significant differences in the marginal bone resorption between the two groups (p > 0.05). conclus...

Journal: :journal of dentistry, tehran university of medical sciences 0
rahab ghoveizi assistant professor, department of prosthodontics, shahid beheshti university of medical sciences, school of dentistry, tehran, iran. marzieh alikhasi mohammad-reza siadat hakimeh siadat majid sorouri

crestal bone loss is a biological complication in implant dentistry. the aim of this study was to compare the effect of progressive and conventional loading on crestal bone height and bone density around single osseointegrated implants in the posterior maxilla by a longitudinal radiographic assessment technique.twenty micro thread implants were placed in 10 patients (two implants per patient). ...

Journal: :journal of dentistry, tehran university of medical sciences 0
hakimeh siadat mahnaz arshad assistant professor of tehran university of medical sciences hossein-ali mahgoli babak fallahi

objectives : microbial leakage through the implant-abutment (i-a) interface results in bacterial colonization in two-piece implants. the aim of this study was to compare microleakage rates in three types of replace abutments namely snappy, goldadapt, and customized ceramic using radiotracing. materials and methods: three groups, one for each abutment type, of five implants and one positive and ...

Journal: :journal of dentistry, tehran university of medical sciences 0
aar. rasouli ghahroudi assistant professor, department of periodontology, school of dentistry, tehran university of medical ar talaeepour professor, department of oral and maxillofacial radiology, school of dentistry, tehran university of a. mesgarzadeh associate professor, department of oral and maxillofacial surgery, school of dentistry, tehran unive ar. rokn associate professor, department of periodontology, school of dentistry, tehran university of medical a. khorsand associate professor, department of periodontology, school of dentistry, tehran university of medical nn. mesgarzadeh dentist, private practice

objective: vertical bone loss evaluations in the nobel biocare replace® select tapered tm implant system in the human after one-year loading time. materials and methods: this retrospective cross-sectional study was performed on 31 patients (14 men, 17 women; mean age, 60.39 years) receiving 170 implants (mean, 5.48 for each patient) of groovy and non-groovy designs in the nobel biocare replace®...

Journal: :The Journal of prosthetic dentistry 2008
Luigi Baggi Ilaria Cappelloni Michele Di Girolamo Franco Maceri Giuseppe Vairo

STATEMENT OF PROBLEM Load transfer mechanisms and possible failure of osseointegrated implants are affected by implant shape, geometrical and mechanical properties of the site of placement, as well as crestal bone resorption. Suitable estimation of such effects allows for correct design of implant features. PURPOSE The purpose of this study was to analyze the influence of implant diameter and...

Journal: :The Journal of arthroplasty 1987
D J Bean F R Convery S L Woo R L Lieber

Many investigators consider the polymethylmethacrylate-bone interface the weakest link in the bone-cement-implant system. Push-out tests, frequently used for in vitro evaluation of the bone-cement interface, produced inconsistent results of shear strength. Therefore, a more reliable model for testing the shear failure of the interface was developed. Better understanding of intrinsic variations ...

Journal: :Journal of physics 2022

Abstract Implant denture is the most essential method of oral repair, and its processing depends heavily on precision machining center. Most special machine tools do not take into account requirement automatic parts. During processing, parts need to be double-clamped, which changes geometry In this paper, a small tool with seven axes has been developed realize implant dentures. Firstly, technol...

Journal: :Dento maxillo facial radiology 2013
L Vazquez Y Nizamaldin C Combescure R Nedir M Bischof D M Dohan Ehrenfest J-P Carrel U C Belser

OBJECTIVES Conventional panoramic radiography, a widely used radiographic examination tool in implant treatment planning, allows evaluation of the available bone height before inserting posterior mandibular implants. Image distortion and vertical magnification due to projection geometry is well described for rotational panoramic radiographs. To assess the accuracy of vertical height measurement...

Journal: :Clinical oral implants research 2002
Marc Quirynen Marc De Soete Daniel van Steenberghe

The use of oral implants in the rehabilitation of partially and fully edentulous patients is widely accepted even though failures do occur. The chance for implants to integrate can for example be jeopardised by the intra-oral presence of bacteria and concomitant inflammatory reactions. The longevity of osseointegrated implants can be compromised by occlusal overload and/or plaque-induced peri-i...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید