نتایج جستجو برای: implant interface
تعداد نتایج: 250662 فیلتر نتایج به سال:
Short stemmed hip endoprostheses represent a relevant alternative to standard sized total hip stems. Especially in terms of bone stock preservation and minimal invasiveness the reduced length of such implants is beneficial. However, the smaller implant size is linked to a reduced surface geometry and thereby bone-implant-interface to provide implant stability. In order to evaluate the interfaci...
BACKGROUND The aim of this study is to evaluate the implant survival, the implant-crown success, and the prosthetic complications of 2,549 Morse taper interference-fit connection implants. METHODS A total of 2,549 Morse taper connection implants were inserted in 893 patients from January 2003 until December 2008. At each annual recall, clinical, radiographic, and prosthetic parameters were as...
AIM This study aimed to evaluate the effect of different implant angulations in posterior maxilla on stress distribution by finite element analysis and verify its results experimentally. METHODS Two simplified models were prepared for an implant placed vertically and tilted 25° piercing the maxillary sinus. Geometric models' components were prepared by Autodesk Inventor then assembled in ANSY...
PURPOSE Finite element study on the effect of abutment length and material on implant bone interface against dynamic loading. MATERIALS AND METHODS Two dimensional finite element models of cylinderical implant, abutments and bone made by titanium or polyoxymethylene were simulated with the aid of Marc/Mentat software. Each model represented bone, implant and titanium or polyoxymethylene abutm...
Titanium implants can fail due to inappropriate biomechanics at the bone-implant interface that leads to suboptimal osseointegration. Titania nanotubes (TNTs) fabricated on Ti implants by the electrochemical process have emerged as a promising modification strategy to facilitate osseointegration. TNTs enable augmentation of bone cell functions at the bone-implant interface and can be tailored t...
The objective of this investigation is to analyze the influence of trabecular microstructure modeling on the biomechanical distribution of the implant-bone interface. Two three-dimensional finite element mandible models, one with trabecular microstructure (a refined model) and one with macrostructure (a simplified model), were built. The values of equivalent stress at the implant-bone interface...
In this paper the variation of normal and shear stresses along a path defined on the bone-dental implant interface is investigated. In particular, the effects of implant diameter, collar length and slope, body length, and the effects of four different types of external threads on the interfacial stress distribution are studied. The geometry of the bone is digitized from a CT scan of a mandibula...
....................................................................................................................................7 POPULÄRVETENSKAPLIG SAMMANFATTNING...................................................................9 LIST OF PAPERS........................................................................................................................ 11 MY CONTRIBUTIONS TO IN...
Background and Aims: Hydroxyapatite coating has allocated a special place in dentistry due to its biocompatibility and bioactivity. The purpose of this study was to evaluate the relation between the hydroxyapatite thickness and stress distribution by using finite element method. Materials and Methods: In this paper, the effect of hydroxyapatite coating thickness on dental implants was studi...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید