نتایج جستجو برای: instantaneous reactive compensation
تعداد نتایج: 216498 فیلتر نتایج به سال:
Power quality issues are becoming a major concern of today's power system engineers. Shunt active power filter (SAPF) is one of the effective means for harmonic current compensation in electrical power system. The performance and dynamic characteristics of a three-phase SAPF with a simple control algorithm is presented and analyzed in this paper. This algorithm operates at fixed switching frequ...
In India with a power shortage of about 10% of installed capacity, the transmission and distribution losses are relatively high. One of the reasons for the large loss is the excessive reactive loads on the primary distribution feeder. With the right amount of reactive power compensation, as system load varies, line losses can be considerably reduced. The application of Artificial Neural Network...
Question: Are there general life-history rules for exploitation-caused extinction of mammal populations? Mathematical methods: A population of size N faced with the added mortality of human exploitation will deterministically go extinct if its per-capita birth rate can no longer match its per-capita mortality rate as N approaches zero. We develop exploitation-extinction theory for a mammal life...
To achieve accurate reactive power and harmonic currents sharing among inverter interfaced distributed generation (DG) units in islanded microgrids, a hierarchal control scheme consisting of primary and secondary levels based on instantaneous circulating currents is proposed in this paper. Firstly, fundamental and main harmonic components of each inverter output current are extracted at the pri...
In order to satisfy the requirement of terrain mapping in real-time, this paper solves the problem of too large computation in the traditional interferometric processing algorithm, and provides the algorithm to generate real-time unwrapped phase with high quality based on airborne dual-antenna InSAR system. It utilizes non-linear ECS autoregistration imaging algorithm to generate high accuracy ...
This paper presents detailed modeling and simulation of a compensator for Load balancing and harmonics Compensation based on a five-level cascaded H-bridge multilevel voltage source inverter. This type of compensator, which is installed in parallel with the load, is usually referred to as the shunt active power filters (APF). Nowadays use of high voltage non-linear loads are widely used in indu...
Active power filters are used to eliminate current harmonics of non-linear loads. This paper evaluates three different methods of determining the compensating current for a shunt active filter that is working under nonsymmetrical conditions. The paper compares the instantaneous reactive power theory, the synchronous reference frame theory and fast Fourier transform techniques. The comparison is...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید