نتایج جستجو برای: intraocular lens power calculation formula

تعداد نتایج: 724342  

2013
Dong Hui Lim Sung-Ho Choi Tae-Young Chung Eui-Sang Chung

PURPOSE To assess the refractive change and prediction error after temporary intraocular lens (IOL) removal in temporary polypseudophakic eyes using IOL power calculation formulas and Gills' formula. METHODS Four consecutive patients (7 eyes) who underwent temporary IOL explantation were enrolled. Postoperative refractions calculated using IOL power calculation formulas (SRK-II, SRK-T, Hoffer...

Journal: :BMC veterinary research 2018
Ulrike Meister Christiane Görig Christopher J Murphy Hubertus Haan Bernhard Ohnesorge Michael H Boevé

BACKGROUND Phacoemulsification and intraocular lens (IOL) implantation during cataract surgery in horses occur with increasing frequency. To reduce the postoperative refractive error it is necessary to determine the proper IOL power. In the present study retinoscopy, keratometry and ultrasonographic biometry were performed on 98 healthy equine eyes from 49 horses. The refractive state, corneal ...

Journal: :Archives of ophthalmology 1997
Monica T P Odenthal Cathrien A Eggink Gerrit Melles Jan H Pameyer Annette J M Geerards W Houdijn Beekhuis

OBJECTIVE To assess intraocular lens (IOL) power calculations in patients undergoing cataract surgery after excimer laser photorefractive keratectomy (PRK) for myopia. METHODS Four eyes of two patients underwent phacoemulsification with IOL implantation after PRK for myopia. The estimated refractive error that would have been induced had the IOL predicted for emmetropia been implanted was cal...

Journal: :The British journal of ophthalmology 2001
C Tromans P M Haigh S Biswas I C Lloyd

AIMS To determine the accuracy of intraocular lens (IOL) power calculation in a group of pseudophakic children. METHODS A retrospective analysis of biometric and refractive data was performed on 52 eyes of 40 infants and children, who successfully underwent cataract extraction and IOL implantation. The following parameters were included: age at the time of surgery, keratometry, axial length, ...

Journal: :Journal of refractive surgery 2014
Michael J Simpson W Neil Charman

The calculation of the intraocular lens (IOL) power required for a specific patient typically uses a “lens constant” back-calculated from the refractive outcomes of earlier surgical results.1,2 An early recommendation was for clinicians to personalize their own lens constants to address systematic errors. However, the introduction of phacoemulsification equipment, continuous curvilinear capsulo...

Journal: :The British journal of ophthalmology 1982
J S Hillman

A series of 50 eyes received an intraocular lens (IOL) of power calculated for emmetropia from data of axial length, corneal curvature, and postoperative anterior chamber depth by R. D. Binkhorst's formulae. The postoperative refraction results were compared with those of 100 control eyes which received +19 D standard power IOLs without calculation. The calculated group had postoperative refrac...

Journal: :Journal of cataract and refractive surgery 1992
Sverker Norrby

PURPOSE To identify and quantify sources of error in the refractive outcome of cataract surgery. SETTING AMO Groningen BV, Groningen, The Netherlands. METHODS Means and standard deviations (SDs) of parameters that influence refractive outcomes were taken or derived from the published literature to the extent available. To evaluate their influence on refraction, thick-lens ray tracing that a...

Journal: :Japanese journal of ophthalmology 1998
T Ishikawa A Hirano J Inoue K Nakayasu A Kanai K Takeuchi T Kanda

We reviewed the SRK-II method and introduce a new equation to calculate the intraocular lens (IOL) power for eyes which underwent laser phototherapeutic keratectomy (PTK). The Gullstrand series was used to determine the power and the radius of curvature of planoconvex IOLs which alter the focal point from the cornea to reach the conjugate point on the retina. The radius of anterior corneal curv...

Journal: :The British journal of ophthalmology 1983
J S Hillman

A prospective series of 25 eyes received an intraocular lens (IOL) of power calculated for planned ametropia, by means of the formulae of R. D. Binkhorst, from data of axial length, corneal curvature, and postoperative anterior chamber depth. All the postoperative refractions were within the +/- 2 D range from the predicted refraction, confirming the clinical value of such calculation. A retros...

Journal: : 2021

Purpose: To evaluate the influence of pupil dilation on ocular parameters measured by optical biometry and intraocular lens (PC IOL) power calculation using third-generation (SRK/T) fourth-generation (Haigis) formula. Methods: 40 eyes patients indicated for cataract surgery were included in this study. Each patient was examined biometer firstly without artificial mydriasis (AM) then after AM, w...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید