BACKGROUND For radiotherapy of the head and neck, 5-point mask immobilization is used to stabilize the shoulders. Still, the daily position of the shoulders during treatment may be different from the position in the treatment plan despite correct isocenter setup. The purpose of this study was to determine the interfractional displacement of the shoulders relative to isocenter over the course of...
We have developed a method to improve the setup accuracy of a Varian Clinac 6/100 couch for delivering conformal arc therapy using a tertiary micro multileaf collimator (MLC) system. Several immobilization devices have been developed to improve the mechanical stability and isocenter alignment of the couch: turn-knob harnesses, double-track alignment plates, and a drop-in rod that attaches the c...
This chapter presents an overview of the procedures that are used for the verification of the patient position during radiotherapy. Furthermore, a method for the verification of the radiotherapy isocenter prior to treatment delivery is proposed. The method is based on the alignment of two Computed Tomography (CT) scans: a scan, which is acquired for treatment planning, and an additional verific...
From last 50 years, electron beam therapy has an important radiation therapy modality. The electron beam from the LINAC is of size ∼ 2 mm, whereas the size required for actual treatment is usually larger than 2 × 2 cm up to 25 × 25 cm at the isocenter. In the present work, it is proposed to use dual scattering foil system for production of clinical electron beam. The foils for 6 to 20 MeV elect...
The purpose of this study was to determine the effects of geometric uncertainties of patient position on treatments of multiple nonisocentric intracranial lesions. The average distance between lesions in patients with multiple targets was determined by a retrospective survey of patients with multiple lesions. Retrospective patient imaging data from fractionated stereotactic patients were used t...
The purpose of this study was to investigate the feasibility of using a single QA device for comprehensive, efficient daily QA of a linear accelerator (Linac) and three image-guided stereotactic positioning systems (IGSPSs). The Sun Nuclear Daily QA 3 (DQA3) device was used to perform daily dosimetry and mechanical accuracy tests for an Elekta Linac, as well as daily image geometric and isocent...