نتایج جستجو برای: isolated abutment

تعداد نتایج: 338291  

2015
Fumihiko Watanabe Kazuhiko Hiroyasu Kazuhiko Ueda

BACKGROUND Fractured connections between implants and implant abutments or abutment screws are frequently encountered in a clinical setting. The purpose of this study was to investigate fracture strength using a torsion test at the interface between the implant and the abutment. METHODS Thirty screw-type implant with diameters of 3.3, 3.8, 4.3, 5.0, and 6.0 mm were submitted to a torsion test...

2016
Nicola Mobilio Alberto Fasiol Giulio Franceschetti Santo Catapano

The aim of this study was to qualitatively evaluate the marginal vertical fit along two different implant-abutment interfaces: (1) a standard abutment on an implant and (2) a computer-aided-design/computer-aided-machine (CAD/CAM) customized screw-retained crown on an implant. Four groups were compared: three customized screw-retained crowns with three different "tolerance" values (CAD-CAM 0, CA...

Journal: :The journal of contemporary dental practice 2015
Mohammed Jasim Al-Juboori

Interdental papillae regeneration remains a challenge in implant dentistry in cases in which papillae are lost following tooth extraction. This report presents an implant case with missing 1st and 2nd premolars and total papillary loss. We performed immediate provisionalization to the first premolar implant with a temporary abutment and crown, whereas the second premolar was submerged. Crown co...

Journal: :Coatings 2021

Implant supported dental prostheses are increasingly used in practice. The aim of this narrative review is to present the influence transmucosal surface prosthetic abutment and implant on peri-implant tissue. article describes causes bone loss around implant. Moreover, properties different materials compared discussed. advantages, disadvantages, biomechanical concept implant-abutment connection...

Journal: :Prosthesis 2021

The purpose of this study is to numerically analyze a 3D model an implant under fatigue loads. A bone and V shape were modeled using SolidWorks2008 software. In order obtain exact model, the was assumed as linear orthotropic material. Mechanical loads applied in terms fastening torque abutment mastication force at top crown. tightened into by applying 35 N.cm causing tensile stress within screw...

ژورنال: مجله دندانپزشکی 2019
Amoian, Babak , Gholinia, Hemat , Rezai Dastjerdi, Maryam, Sadeghamalnikraftar, Roxana ,

Background and Aims: Removable partial denture (RPDs) is a common therapy for rehabilitation of partialy edentulous patients while RPD causes a lot of periodontal problems. The purpose of this study was to investigate the effect of RPDs made in Babol dental school on the periodontal health of abutment and non-abutment teeth. Materials and Methods: In this cross sectional study, 70 patients who...

Journal: :The International journal of oral & maxillofacial implants 2012
Christian R Leutert Bogna Stawarczyk Thomas C Truninger Christoph H F Hämmerle Irena Sailer

PURPOSE The aim of this study was to examine the bending moments and fracture patterns of different zirconia abutments with internal implant-abutment connections after static loading and to compare their bending moments to those of internally connected titanium abutments. MATERIALS AND METHODS Three types of customized zirconia abutments (Straumann CARES abutments/Straumann BL implants [T1], ...

Journal: :The International journal of oral & maxillofacial implants 2016
Jee-Ho Lee Ji-Man Park Eun-Jin Park Jai-Young Koak Seong-Kyun Kim Seong-Joo Heo

PURPOSE To investigate the clinical usefulness, a customized abutment produced with the Pd-Ag-In alloy was compared with a customized abutment produced with the conventional titanium alloy for discoloration and mechanical accuracy. MATERIALS AND METHODS Discoloration and resistance to corrosion of the Pd-Ag-In alloy were evaluated using chemical solutions. Marginal adaptation of internal-type...

2016
Luis Pérez Carro

 Two distinct types of FAI: Cam and rim or pincer impingement.  Pincer impingement is believed to result from abnormal extensión/contact (Bony prominence) of the anterior and/or posterior walls or acetabular roof relative to the center of the femoral head, causing an abutment of the acetabular rim against the femoral head-neck junction.  The term pincer impingement was defined in 2003 by Gan...

Journal: :Acta odontologica latinoamericana : AOL 2007
Regênio M H Segundo Hugo M S Oshima Isaac N L Silva Luis H B Júnior Eduardo G Mota Luiz F B Coelho

The aim of this study was to compare and evaluate strain distribution on dental implant, abutment, screw and crown virtual models in the posterior region. The analysis was performed by means of a 3D virtual model developed by the PRO-ENGINEER System (PRO-ENGINEER, PTC, Needham, MA, USA ) with an external butt joint (3i Implant Innovations, Palm Beach, Florida), square headed Gold Tite abutment ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید