Journal: :Radiation protection dosimetry 2006
Christopher Soares Chris Drupieski Brian Wingert Garey Pritchett Vasilis Pagonis Michelle O'Brien Alan Sliski Pawel Bilski Pawel Olko

Absorbed dose rate measurements of a 50 kV(p) handheld X-ray probe source in a water phantom are described. The X-ray generator is capable of currents of up to 40 microA, and is designed for cranial brachytherapy and intraoperative applications with applicators. The measurements were performed in a computer-controlled water phantom in which both the source and the detectors are mounted. Two dif...

2016
Kevin A. Wunderle Joseph T. Rakowski Frank F. Dong

The first goal of this study was to investigate the accuracy of the displayed reference plane air kerma (Ka,r) or air kerma-area product (Pk,a) over a broad spectrum of X-ray beam qualities on clinically used interventional fluoroscopes incorporating air kerma-area product meters (KAP meters) to measure X-ray output. The second goal was to investigate the accuracy of a correction coefficient (C...

2016
Mohammad Taghi Bahreyni Toossi Mahdi Ghorbani Atefeh Rostami Mohsen Khosroabadi Sara Khademi Courtney Knaup

tope has recently been proposed as a hypothetical brachytherapy source due to its high specific activity, appropriate half-life (272 days) and medium energy photons (114.17 keV on average). In this study, Task Group No. 43 dosimetric parameters were calculated and reported for a hypothetical 57Co source. Material and methods: A hypothetical 57Co source was simulated in MCNPX, consisting of an a...

2017
Mahdi Ghorbani Benyamin Khajetash Najmeh Ghatei Mohammad Mehrpouyan Ali S. Meigooni Ramin Shahraini

BACKGROUND Interstitial rotating shield brachytherapy (I-RSBT) is a recently developed method for treatment of prostate cancer. In the present study TG-43 dosimetric parameters of a 153Gd source were obtained for use in I-RSBT. MATERIALS AND METHODS A 153Gd source located inside a needle including a Pt shield and an aluminum window was simulated using MCNPX Monte Carlo code. Dosimetric parame...

2016
Mohammad Taghi Bahreyni Toossi Mahdi Ghorbani Atefeh Rostami Mohsen Khosroabadi Sara Khademi Courtney Knaup

AIM OF THE STUDY The (57)Co radioisotope has recently been proposed as a hypothetical brachytherapy source due to its high specific activity, appropriate half-life (272 days) and medium energy photons (114.17 keV on average). In this study, Task Group No. 43 dosimetric parameters were calculated and reported for a hypothetical (57)Co source. MATERIAL AND METHODS A hypothetical (57)Co source w...

2000
M. P. A. Potiens

INTRODUCTION Quality assurance programmes in diagnostic radiology have been increased in the last years due to the fact that the extensive use of X-rays in medicine for diagnosis of injuries and diseases represents the largest manmade source of public exposure to ionizing radiation (1). The assessment and control of the performance characteristics of X-ray generators and tubes is an essential p...

Journal: :iranian journal of radiation research 0
m.b. tavakoli department of medical physics and medical engineering, school of medicine, isfahan university of medical sciences, isfahan, iran d. shahbazi-gahrouei department of medical physics and medical engineering, school of medicine, isfahan university of medical sciences, isfahan, iran m. hosseinpour department of medical physics and medical engineering, school of medicine, isfahan university of medical sciences, isfahan, iran

background: for an effective treatment planning in brachytherapy, it is necessary to know the accurate source dosimetric information such as air kerma strength, exposure rate constant, dose rate constant and redial dose distribution. the usual method to determine these factors is thermo luminescent dosimeter (tld) dosimetry. nowadays, another more accurate method is known to be the monte carlo ...

A. Solimanian, M. Ghafoori,

Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...

2014
Stephen M Seltzer Michelle O’Brien Michael G Mitch

The new primary standard for low-energy electronic brachytherapy sources for the United States is described. These miniature x-ray tubes are inserted in catheters for interstitial radiation therapy and operate at tube potentials of up to about 50 kV. The standard is based on the realization of the air kerma produced by the x-ray beam at a reference distance in air of 50 cm.

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید