نتایج جستجو برای: liquid membrane electrodes

تعداد نتایج: 632971  

Journal: :journal of petroleum science and technology 2013
mostafa dehghani mobarake ramin karami

in the present study, a new gas diffusion electrode (gde) (based on pt/nafion membrane) is fabricated. the electrochemical results show that the new gde has the highest electrochemical activity toward the oxygen reduction reaction (orr) among the three electrodes. the sem and xrd findings show that a platinum layer can be attached to nafion membrane closely and firmly with a strong peak corresp...

Journal: :Clinical chemistry 1993
R Eugster B Rusterholz A Schmid U E Spichiger W Simon

A magnesium ion-selective liquid membrane electrode based on a synthetic neutral carrier is presented. The selectivity for Mg2+ over Na+, K+, and H+ is sufficient for assays in the physiological range, but a chemometric correction of approximately 10% is still necessary for the Ca2+ interference. We optimized the membrane composition especially with respect to selectivity and accuracy by perfor...

Journal: :Physical review letters 2009
F Muñoz-Rojas J Fernández-Rossier J J Palacios

By computing spin-polarized electronic transport across a finite zigzag graphene ribbon bridging two metallic graphene electrodes, we demonstrate, as a proof of principle, that devices featuring 100% magnetoresistance can be built entirely out of carbon. In the ground state a short zigzag ribbon is an antiferromagnetic insulator which, when connecting two metallic electrodes, acts as a tunnel b...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2007
Shusuke Oosaki Setsuko Yajima Keiichi Kimura

A liquid-crystalline benzocrown ether, 4'-[(4''-1,1,2,2-tetrahydroperfluorooctyloxy)biphenyloxycarbonyl]benzo-15-crown-5, was used as a neutral carrier of ion-selective electrodes (ISEs) to elucidate the effect of highly ordered assembling of the neutral carrier on the sensor properties through fluorophilic interactions. The properties for the membrane and the resulting ISEs based on a benzocro...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2008
Naoya Nishi Hiroshi Murakami Yukinori Yasui Takashi Kakiuchi

The phase-boundary potential at the interface between an aqueous KCl solution (W) and a hydrophobic room-temperature ionic liquid (RTIL), trioctylmethylammonium bis(nonafluorobutylsulfonyl)imide ([TOMA(+)][C(4)C(4)N(-)]), containing dicyclohexano-18-crown-6 (DCH18C6), shows the nernstian response to K(+) in W within a polarized potential window of 500 mV between [TOMA(+)][C(4)C(4)N(-)] and W, d...

2000
GLENN B. MARTIN

A general approach for enhancing the selectivity of anion-responsive liquid-membrane electrodes is described. The method is based on use of the receptor channel of a flowthrough dialyzer unit as the injection loop in a flow-injection system. An appropriate membrane in the dialyzer prevents ionic interferents from reaching an inselective electrode in the final flow stream The concept is demonstr...

2008
Farnoush Faridbod Mohammad Reza Ganjali Rassoul Dinarvand Parviz Norouzi Siavash Riahi

Ionophore incorporated PVC membrane sensors are well-established analyticaltools routinely used for the selective and direct measurement of a wide variety of differentions in complex biological and environmental samples. Potentiometric sensors have someoutstanding advantages including simple design and operation, wide linear dynamic range,relatively fast response and rational selectivity. The v...

Elham Eslami Hashem Sharghi Mojtaba Shamsipur, Nahid Tavakkoli

Two poly(oxyethylene) derivatives 1.10-bis(2'-benzoic acid)-1,4,7,1-tetradecane (L1) and 1,7-bis(2'-benzoic acid)-1,4,7-trioxaheptane (L2) were used as suitable ionophores for the preparation of potassium-selective PVC-membrane electrodes. The resulting electrodes based on L1 and L2 exhibit linear responses to the activity of K+ ions within the concentration ranges of 3.1<em...

2015
Ricardo Couto Luísa Neves Pedro Simões Isabel Coelhoso

In this work, a supported ionic liquid membrane (SILM) was prepared by impregnating a PVDF membrane with 1-butyl-3-methylimidazolium dicyanamide ([BMIM][DCA]) ionic liquid. This membrane was tested for its permeability to pure gases (CO2, N2 and O2) and ideal selectivities were calculated. The SILM performance was also compared to that of Ion-Jelly® membranes, a new type of gelled membranes dev...

Journal: :Energy & environmental materials 2021

Direct liquid fuel cells (DLFCs) are proposed to address the problems of high cost and complex storage transportation hydrogen in traditional hydrogen–oxygen proton exchange membrane cells. However, present fuels organic small molecules used DLFCs restricted sluggish electrochemical kinetics easily poisoning precious metal catalysts. Herein, we demonstrate reduced phosphotungstic acid as a for ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید