نتایج جستجو برای: locking plate

تعداد نتایج: 83531  

2014
Seong-Man Lee Chang-Wug Oh Jong-Keon Oh Joon-Woo Kim Hyun-Joo Lee Chang-Soo Chon Byoung-Joo Lee Hee-Soo Kyung

BACKGROUND To determine relative fixation strengths of a single lateral locking plate, a double construct of a locking plate, and a tibial nail used in treatment of proximal tibial extra-articular fractures. METHODS Three groups of composite tibial synthetic bones consisting of 5 specimens per group were included: lateral plating (LP) using a locking compression plate-proximal lateral tibia (...

2016
Chun Bi Qiugen Wang Christopher Nagelli Jianhong Wu Qian Wang Jiandong Wang

BACKGROUND The aim of this study was to assess the clinical results of treatment for unstable posterior pelvic fractures using a pedicle screw-rod fixator compared to use of a locking compression plate. MATERIAL AND METHODS A retrospective study was performed between June 2010 and May 2014 and the data were collected from 46 patients with unstable posterior pelvic ring fractures. All patients w...

2017
Jixing Fan Yufu Zhang Qiang Huang Xieyuan Jiang Liang He

BACKGROUND Surgical managements were recommended for unstable distal clavicle fracture owing to the high incidence of nonunion. The present study compared the efficacy of anatomical locking plate with versus without additional suture anchor fixation for the treatment of unstable Neer type II distal clavicle fractures. MATERIAL AND METHODS Between January 2013 to January 2015, 28 consecutive pat...

Journal: :Journal of orthopaedic surgery 2013
Anoop C Dhamangaonkar Deepak Joshi Arvind B Goregaonkar Akhil A Tawari

PURPOSE To compare the outcome in patients who underwent surgery for unstable intertrochanteric femoral fractures using the proximal femoral locking plate versus the dynamic hip screw (DHS). METHODS 15 men and 5 women aged 32 to 78 (mean, 55) years were randomised to the proximal femoral locking plate group, whereas 14 men and 6 women aged 38 to 75 (mean, 59) years were randomised to the conv...

2016
Herwig Drobetz Lidia Koval Patrick Weninger Ruth Luscombe Paula Jeffries Stefan Ehrendorfer Clare Heal

AIM To compare the outcomes of displaced distal radius fractures treated with volar locking plates and with immediate postoperative mobilisation with the outcomes of these fractures treated with modalities that necessitate 6 wk wrist immobilisation. METHODS A prospective, randomised controlled single-centre trial was conducted with 56 patients who had a displaced radius fracture were randomis...

2015

Background: A variety of treatment modalities are available for fracture of distal radius. However, there is a lack of consensus on the preferred treatment in these cases. Aims: To compare the different methods for the treatment fracture of distal part of the radius based on the outcome at the end of treatment. Methods: Analysis of cases with fracture of distal radius treated at our centre over...

2016
Sergi Barrera-Ochoa Sergi Rodríguez-Alabau Andrea Sallent Francisco Soldado Xavier Mir

We report a 38-year-old male with a nonunion followed by plate breakage after volar plating of a distal radius osteotomy. Volar locking plates have added a new approach to the treatment of distal radius malunions, due to a lower morbidity of the surgical approach and the strength of the final construction, allowing early mobilization and return to function. Conclusion. Plate breakage is an unco...

2014
Wen Zhang Langqing Zeng Yanjie Liu Yao Pan Wei Zhang Changqing Zhang Bingfang Zeng Yunfeng Chen

BACKGROUND The purpose of this study was to evaluate the biomechanical advantages of medial support screws (MSSs) in the locking proximal humeral plate for treating proximal humerus fractures. METHODS Thirty synthetic left humeri were randomly divided into 3 subgroups to establish two-part surgical neck fracture models of proximal humerus. All fractures were fixed with a locking proximal hume...

Journal: :The Journal of hand surgery 2016
J Sawyer Croley Randal P Morris Arsalan Amin Ronald W Lindsey Zbigniew Gugala

PURPOSE The objective of this study was to assess the biomechanical properties of bicortical locking screws, unicortical locking screws, and unicortical far-cortex-abutting locking screw fixation in a cadaver model of comminuted midshaft clavicle fractures stabilized with a locking plate placed on the superior surface of the clavicle. METHODS Nine pairs of adult fresh-frozen cadaver clavicles...

2014
Meng-Hsuan Lee Chien-Jen Hsu Kai-Cheng Lin Jenn-Huei Renn

BACKGROUND Tibial plateau fracture (TPF) includes different fracture patterns with varied degrees of articular depression and displacement. Many kinds of fixators, including newly designed plate with locking screws, were applied to treat these complicated fractures. We intended to follow up the surgical outcomes of (1) unilateral locking plate, (2) classic dual plates, or (3) hybrid dual plates...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید