نتایج جستجو برای: mathematical head phantom

تعداد نتایج: 394361  

2005
Gaetano Compagnone Laura Pagan Carlo Bergamini

Entrance skin dose (ESD) is an important parameter for assessing the dose received by a patient in a single radiographic exposure. The most useful way to evaluate ESD is either by direct measurement on phantoms using an ionization chamber or using calculations based on a mathematical model. We compared six phantoms (three anthropomorphic, two physical, and one mathematical) in 11 standard clini...

2013
Larissa Thompson Humberto Galvão Dias Tarcísio Passos Ribeiro Campos

Glioblastoma multiforme (GBM) is the most common, aggressive, highly malignant and infiltrative of all brain tumors with low rate of control. The main goal of this work was to evaluate the spatial dose distribution into a GBM simulator inside a head phantom exposed to a 15 MV 3D conformal radiation therapy in order to validate internal doses. A head and neck phantom developed by the Ionizing Ra...

2014
Lei Fu Harold Perera Xiao Ying Yan Yu

The purpose of this study is to quantify the discrepancy between optical guidance platform (OGP) frameless localization system (Varian) and Trilogy on-board imaging (OBI) system (Varian) for setting up phantom and stereotactic radiosurgery (SRS) patient; and to determine whether cone-beam CT (CBCT) is necessary for OGP patient setup, and compare CBCT and orthogonal kV-kV in term of their verifi...

A. Ghasemzadeh H. Ghanaati H. Hashemi M. Ashkanmehr M. Bakhtiary M. Pakravan M.A. Oghabian N. Riyahi Alam N. Shakeri

Introduction:  Image  distortion  is  one  of  the  major  problems  of  magnetic  resonance  imaging  (MRI) for use in 3DMRI, velocity MRI, FMRI and radiotherapy treatment planning (RTTP). It is  widely known that the most obvious effect of the inhomogenity of the magnetic fields and the  nonlinearity  of  the  gradient  is  the  Geometric  Distortion  of  MR  tomograms.  In  this  study,  the...

E. Hoseinian Azghadi, H. Miri Hakimabad L. Rafat Motavalli

Annually, many people are irradiated for diagnostic and therapeutic purposes. Assessment of radiation dose and its related risks to patients are important issues in radiation protection dosimetry. The complex mathematical calculations of the absorbed and effective doses are now done with computers. The calculations are performed with the help of anthropomorphic computational models of human bod...

Journal: :journal of biomedical physics and engineering 0
n mohammadi s h miri-hakimabad l rafat-motavalli

background: high-energy linear accelerator (linac) is a valuable tool and the most commonly device for external beam radiation treatments in cancer patients. in the linac head, high-energy photons with energies above the threshold of interaction produce photoneutrons. these photoneutrons deliver the extra dose to the patients in the planning treatment and increase the risk of secondary cancer. ...

ژورنال: سنجش و ایمنی پرتو 2014

During the radiation therapy with electron beam, due to electron interaction and scattering from structures of the head of the medical linear accelerator, unwanted photons are produced. The main contribution of the photon contamination is resulted from the various components of the medical linear accelerator on the way of the high energy electron beam, and few percent is due to the interaction ...

Journal: :International journal of radiation oncology, biology, physics 2011
Harry C Y Cheng Vincent W C Wu Eva S F Liu Dora L W Kwong

PURPOSE To compare the image quality and dosimetry on the Varian cone beam computed tomography (CBCT) system between software Version 1.4.13 and Version 1.4.11 (referred to as "new" and "old" protocols, respectively, in the following text). This study investigated organ absorbed dose, total effective dose, and image quality of the CBCT system for the head-and-neck and pelvic regions. METHODS ...

2013
K. Erb-Eigner C. Warmuth M. Taupitz G. Willerding E. Bertelmann P. Asbach

Purpose: Generally, high-resolution MRI of the eye is performed with small loop surface coils. The purpose of this phantom and patient study was to investigate the influence of magnetic field strength and receiver coils on image quality in ocular MRI. Materials and Methods: The eyeball and the complex geometry of the facial bone were simulated by a skull phantom with swine eyes. MR images were ...

2017
Chulhwan Hwang Ja Mee Kim JungHoon Kim

The purpose of this study was to analyse the effects of the type, concentration, and nanoparticle diameter of dose enhancement materials on the dose enhancement of low- and high-energy megavoltage (MV) X-rays acquired from a medical linear accelerator using Monte Carlo simulation. Monte Carlo simulation was performed with the Monte Carlo N-Particle Transport (MCNPX) code, using the energy spect...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید